(A) General requirements. Every park shall contain an electrical wiring system consisting of wiring, fixtures, equipment and appurtenances which shall be installed and maintained in accordance with local electric power company’s specifications regulating such systems.
(B) Power distribution lines.
(1) Main power lines must be located underground in accordance with Pennsylvania Public Utility Commission order of July 8, 1970, ID. 99.
(2) All direct burial conductors or cable shall be buried and shall be insulated and specially designed in accordance with the local power company specifications or electrical code.
(C) Individual electrical connections. Each mobile home lot shall be provided with an approved disconnecting device and overcurrent protective equipment. The minimum service per outlet shall be 120/240 volts AC, 100 amperes.
(D) Required grounding. All exposed non-current-carrying metal parts of mobile homes and all other equipment shall be grounded by means of an approved grounding conductor run with branch circuit conductors or other approved method of grounded metallic wiring. The neutral conductor shall not be used as an equipment ground for mobile homes or other equipment.
(2003 Code, § 146-58) (Ord. 2-96, passed 7-5-1996)