(A) An accessible, adequate, safe and potable supply of water shall be provided in each park, capable of furnishing a minimum of 250 gallons per day, per mobile home space. Where a public supply of water of such quality is available within 300 feet or becomes available within 300 feet, connection shall be made thereto and its supply shall be used exclusively. Where private water supplies must be developed, the health officer must approve the location, construction and development of the water well, pipe system and connections. No private source other than a water well shall be used.
(B) The water system of the mobile home park shall be connected by pipes to all buildings and all mobile home spaces. Each mobile home shall be provided with a cold water tap at least four inches above the ground. An adequate supply of hot water shall be provided at all times in the service buildings for all bathing, washing, cleansing and laundry facilities.
(C) All water piping shall be constructed and maintained in accordance with state and local law. The water piping system shall not be connected with nonpotable or questionable water supplies and shall be protected against the hazards of backflow or back-siphonage. All water connections shall be weathertight.
(D) Where drinking fountains are provided for public use, they shall be of a type and in a location approved by the health officer.
(E) Individual water-service connections which are provided for direct use by mobile homes or travel trailers shall be of such construction so that they will not be damaged by the parking of such mobile homes or travel trailers. The park system shall be adequate to provide 20 pounds per square inch of pressure at all mobile home or travel trailer connections.
(F) Provisions shall be made within 150 feet of each travel trailer space to supply water for travel trailer reservoirs.
(G) No well-casing, pumps, pumping machinery or suction pipes shall be located in any pit, room or space extending below ground level, nor in any room or space above ground which is walled in or otherwise enclosed unless such rooms, whether above or below ground, have free drainage by gravity to the surface. All floors shall be watertight and slopes from the pump pedestal to the drain, and floors shall extend at least two feet from the well in all directions. The pedestal shall not be less than 12 inches above the floor. This shall not be construed as prohibiting submersible pumps.
(H) All water storage reservoirs shall be watertight and constructed of impervious material; all overflows and vents of such reservoirs shall be effectively screened. Open reservoirs are prohibited. Manholes shall be constructed with overlapping covers so as to prevent the entrance of contaminated material. Overflow pipes from a reservoir shall not connect to any pipe in which sewage or polluted water may back up.
(I) Underground stop and waste-cocks shall not be installed on any connections.
(J) No water well shall draw water from any sands reserved to the town for its use, except as may be otherwise permitted by ordinances of the town.
(K) No water connections shall be made to travel trailer spaces.
(`85 Code, § 13-18)