(A) The subdivider shall submit on Mylar or reproducible material a plan, profile, and typical cross-section for each proposed street in the subdivision. Water and sewer mains, with grades and pipe sizes, shall normally be shown on the same plan; however, the Planning Commission may require water and sewer mains to be shown on separate plan and profile sheets. A minimum scale of one inch equal to 50 feet for plans and one inch equal to five feet for profiles shall be maintained unless otherwise authorized by the Planning Commission. A sheet size of 24 inches by 36 inches drawn with reproducible ink or pencil shall be used.
(B) Plans shall follow:
(1) Right-of-way lines of thoroughfares, streets, alleys, and easements, and location of street and surface therein;
(2) Centerlines of thoroughfares, streets, and easements;
(3) Data on the location, length, and bearings of all lines, including length of radii, arcs, tangents, and curves. Central angles and street curves may be referred to a curve table;
(4) Location of storm and sanitary sewers and water mains and items that pertain thereto, such as manholes, hydrants, valves, and the like;
(5) All bearing lines shall be referred to established section lines, whenever possible; and
(6) All subsurface utilities, existing or proposed, shall be shown on the plans, whenever possible, and be in accordance with the State Utilities Protection Service.
(C) Profile shall show:
(1) Centerline elevations, percent of grade and location and length of vertical curves on all streets;
(2) Elevations shall be based on United States Geodetic Survey Datum and permanent benchmarks whenever possible; and
(3) At least one site benchmark references to U.S.G.S. shall be shown on the plan/profile sheet.
(Prior Code, § 1252.13) (Ord. 2000-9, passed 9-11-2000) Penalty, see § 153.999