§ 1440.10 PREMANUFACTURED UNIT STANDARDS.
   (a)   All mobile homes shall be anchored to resist flotation, collapse or lateral movement by providing over-the-top and frame ties in accordance with the following specifications.
      (1)   Over-the-top ties shall be provided at each of the four corners on the structure, with two additional ties per side at intermediate locations, except that on structures less than 50 feet in length one tie per side shall be required.
      (2)   Frame ties shall be provided at each corner of the structure with five additional ties per side at intermediate points, except that on structures less than 50 feet in length four ties per side shall be required.
      (3)   All components of the anchoring system shall be capable of carrying a force of 4,800 pounds.
      (4)   All additions to premanufactured structures shall be similarly anchored.
   (b)   An evacuation plan indicating alternative vehicular access and escape routes shall be filed with the City Emergency Disaster Coordinator for mobile home parks and mobile home subdivisions.
   (c)   Mobile homes within Zones A1-30 on the Flood Insurance Rate Map shall be located in accordance with the following standards.
      (1)   All mobile homes shall be placed on stands or lots which are elevated on compacted fill or on pilings so that the lowest floor of the mobile home will be at or above the base flood level.
      (2)   Adequate surface drainage away from all structures and access for a mobile home hauler shall be provided.
      (3)   In the instance of elevation on pilings, lots shall be large enough to permit steps, piling foundations shall be placed on stable soil no more than ten feet apart. Reinforcement shall be provided for piers more than six feet above ground level.
      (4)   In mobile home parks and mobile home subdivisions which exist at the time this section is adopted, where repair, reconstruction or improvement of streets, utilities and pads equals or exceeds 50% of the value of the streets, utilities and pads before the repair, the standards in divisions (c)(1), (c)(2) and (c)(3) above shall be complied with.
(Ord. 220, passed 2-13-1991)