1296.06   SETBACKS.
   (a)   Occupied Buildings.
      (1)   Wind turbines shall be set back from the nearest occupied building, the greater of a distance equal to the collapse zone of the wind turbine plus ten feet or 1.1 times its total height. The setback distance shall be measured from the center of the wind turbine base to the nearest point on the foundation of the occupied building.
      (2)   Wind turbines shall be set back from the nearest occupied building located on a non-participating landowner's property, the greater of a distance of not less than thirty feet as measured from the center of the wind turbine base to the nearest point on the foundation of the occupied building.
   (b)   Property Lines. All wind turbines shall be set back from the nearest property line, the greater of a distance equal to the collapse zone of the wind turbine plus ten feet or 1.1 times its total height. The setback distance shall be measured to the center of the wind turbine base.
   (c)   Public roads. All wind turbines shall be set back from the nearest public right-of-way a distance equal to the collapse zone of the wind turbine plus ten feet or 1.1 times its total height. The setback distance shall be measured to the center of the wind turbine base.
(Ord. 11-014. Passed 6-7-11.)