§ 52.17 REQUIRED INFORMATION.
   In support of the application, the industrial user shall submit, in units and terms appropriate for evaluation, the following information.
   (A)   Corporate or individual name, any assumed name(s), federal employer identification number, address, and location of the discharging facility.
   (B)   Name and title of the authorized representative of the industrial user who shall have the authority to bind the industrial user financially and legally.
   (C)   All SIC numbers of all processes at this location according to the Standard Industrial Classification Manual, issued by the Executive Office of the President, Office of Management and Budget, 1972, as amended.
   (D)   Actual or proposed wastewater constituents and characteristics for each parameter listed in the permit application form. The parameters shall include those applicable pollutants having numeric limitations and those pollutants limited by national categorical pretreatment standards or regulations for applicable industries. For each parameter, the expected or experienced maximum and average concentrations during a one-year period shall be provided. For industries subject to national categorical pretreatment standards or requirements, the date requested herein shall be separately shown for each categorical process waste stream. Combined waste streams proposed to be regulated by the combined waste stream formula shall also be identified. Sampling and analysis shall be performed in accordance with procedures established by the EPA pursuant to Section 304(g) of the Act and contained in 40 CFR, Part 136, as amended, (where 40 CFR, Part 136 does not include a sampling or analytical technique for the pollutant in question, sampling and analysis shall be performed in accordance with the procedures set forth in the EPA publication, Sampling and Analysis Procedures for Screening of Industrial Effluents for Priority Pollutants, April, 1977, and amendments or revisions thereto) or with any other sampling and analytic procedures, where appropriate and applicable, approved by the EPA; the name and address of the laboratory performing the analytical work.
   (E)   A listing and description of activities, facilities and plant processes on the premises. Those processes which are subject to national categorical pretreatment standards or requirements shall be so designated. As pertains to division (D) above, identification of which pollutants are associated with each process.
   (F)   Restricted to only those pollutants referred to in division (D) above, a listing of raw materials and chemicals that are either used in the manufacturing process or could yield the pollutants referred to in division (D) above. Any user claiming immunity from having to provide this information for reasons of national security shall furnish acceptable proof of immunity.
   (G)   A description of typical daily and weekly operating cycles for each process in terms of starting and ending times for each of the seven days of the week.
   (H)   Average and maximum 24-hour wastewater flow rates, including daily, monthly and seasonal variations, if any; list each national categorical process waste stream flow rate and the cooling water, sanitary water and storm water flow rates separately for each connection to the POTW; list each combined waste stream.
   (I)   A drawing showing all sewer connections and sampling manholes by the size, location, elevation and points or places of discharges into the POTW; also a flow schematic showing which connections receive each national categorical process waste stream and which connections receive storm water, sanitary water or cooling water; also show which lines handle each combined waste stream. This schematic shall be cross-referenced to the information furnished in division (H) above.
   (J)   Each product produced by type, amount, process, or processes and rate of production as pertains to processes subject to production based limits under the national categorical standards or requirements only.
   (K)   A statement regarding whether or not the requirements of this chapter and the national categorical pretreatment standards and requirements are being met on a consistent basis and, if not, what additional operation and maintenance work and/or additional construction is required for the industrial user to meet the applicable standards and requirements.
   (L)   Basic information on the spill containment program and the program for the prevention of accidental discharges for each of the pollutants referred to in division (D) above. The information provided shall include the approximate average and maximum quantities of substances kept on the premises in the form of raw materials, chemicals and/or wastes therefrom and the containment capacity for each. Only substances which are in a form which could readily be carried into the POTW and which constitute a concentration of 5% or greater on a dry weight basis in the raw material, chemical solution or waste material are required to be reported. Volumes of less than 55 gallons or the equivalent thereof need not be reported unless lesser quantities could cause pass-through or cause interference with the POTW.
   (M) Proposed or actual hours of operation of each pretreatment system for each production process.
   (N)   A schematic and description of each pretreatment facility. Identify whether each pretreatment facility is of the batch type or continuous process type.
   (O)   If other than DWSD potable water, the industrial user's source of intake water together with the types of usage and disposal method of each water source and the estimated wastewater volumes from each source.
   (P)   If additional construction and/or operation and maintenance procedures will be required to meet the requirements of this chapter and the national categorical standards, the shortest schedule by which the user will provide any additional construction and/or implement the required operation and maintenance procedures.
   (Q)   Any other information as may reasonably be required to prepare and process a wastewater discharge permit.
(‘83 Code, § 54.07(B)) (Ord. 89-009, passed 8-21-89) Penalty, see § 52.99