15.30.100. Transportation Demand Management strategies to reduce single occupant vehicles.
   A.   Applicability:
      1.   This section shall apply to all new commercial development or major expansion of existing commercial development that are estimated to employ one hundred or more persons as determined by the methodology in Subsection B of this section.
      2.   For purposes of determining whether a new development project is subject to this section, the total employment figure will be determined as follows:
         a.   An employment projection developed by the applicant, subject to approval by the Director of Development Services.
         b.   An employment projection using the following employee generation factors by type of use:
      Land Use Category         Gross Sq. Ft./Employee
      Commercial            500
      Office/Professional         250
      Hotel               0.8/room
         c.   The employment projection for a development of mixed or multiple uses shall be calculated on a case-by-case basis based upon the proportion of development devoted to each type of use.
   B.   Facility standards:
      1.   A minimum of ten percent of parking spaces, located as close as is practical to the entrance(s) of the use they are intended to serve, shall be reserved and adequately signed for use of carpool and vanpool vehicles.
      2.   Secure, adequate and convenient storage shall be provided for bicycles.
      3.   Bus bays, bus stops and bus shelters shall be provided where appropriate.
      4.   A commuter information area or multiple areas shall be provided within or near each building; the information area(s) shall be centrally located and accessible to all employees and tenants; information shall include, but not be limited to, current maps, routes and schedules for public transit.
      5.   A shower and locker room facility for employees of each sex shall be provided in each building of 100,000 gross square feet or more. Any development containing a combined total of 100,000 gross square feet, but which does not contain any single building exceeding 100,000 gross square feet, shall provide shower and locker room facilities unless a finding is made that the provision of such facilities is not practical or efficient.
      6.   Sidewalks or other paved pathways following direct and safe routes from the external pedestrian circulation system to each building in the development shall be provided.
   C.   Monitoring:
   Periodic monitoring of the developments may occur to ensure full and continued implementation of the facility standards, as described in Subsection B of this section.
(Ord. 3066, (part), 2005: Ord. 2982, 2001)