§ 151.39  IMPROVEMENT PLAN REQUIREMENTS.
   The improvement plan that is to be provided by the subdivider shall not be greater than 36 inches in the longest dimension and shall include the following information:
   (A)   Location map;
   (B)   Subdivision name and location;
   (C)   North arrow and scale;
   (D)   Title block with name and address of the developer, engineering firm and engineer’s seal; and
   (E)   One or more bench marks in or near the subdivision to which the subdivision is referenced. The elevation shall be based on the mean-sea-level datum;
   (F)   Plans, profiles and cross sections of streets surface width, rights-of-way, elevations, grades, roadway details, curbs and gutters, drainage facilities, sidewalks and any other improvements to be constructed. Plans and profiles of streets and other improvements shall be scaled not less than one inch equals 100 feet horizontal and one inch equals ten feet vertical;
   (G)   Location and size of existing and proposed utilities;
   (H)   Contours based on mean-sea-level datum (USGS digitized contours will not be accepted);
   (I)   List of the standards and specifications followed;
   (J)   An estimate by a professional engineer for the cost of all improvements;
   (K)   Draft of protective covenants;
   (L)   Compliance with the requirements of the National Flood Insurance Program, as adopted by the County Board; and
   (M)   Erosion and sediment control plan, if required the E.P.A.
(Ord. 2013-04, passed 5-6-2013)