§ 96.22 ENGINEERING PLANS; SPECIFICATIONS.
   (A)   All preparation of plans, specifications, construction and inspection within a municipal right-of-way shall be performed under the supervision of a Civil Engineer registered in the state and employed by the owner, who shall be the Engineer of Record. This provision shall only apply if the project is of the size or importance that the Director of Public Works deems it necessary.
   (B)   Plans shall be submitted on a maximum size sheet of 24 inches by 36 inches and must be neat, clear, legible and complete in all respects. Profiles will be required in projects involving installation of sewer and underground irrigation lines in dedicated rights-of-way. Power facilities must also be submitted in profile where the trade size of a single conduit exceeds six inches in diameter or where multiple conduits including the concrete encasements are 60 square inches or greater in cross-section areas. In addition, profiles may be required by the Director of Public Works in cases of possible alignment or grade conflicts, cover problems or crossing conflicts. Plans may be submitted concurrently with the application for a construction permit but at least 14 working days will be required for review.
   (C)   The Director of Public Works shall require submission of a set of as-built plans in all cases.
(Prior Code, Ch. 16, Art. II, § 16-34) (Ord. 55, passed 12-15-1983)