§ 50.022 DETERMINATION OF AMOUNT OF SEWAGE.
   (A)   Residential sanitary sewage. The average flow of sanitary sewage shall be computed on the basis of 100 gallons per capita. The peak flow for various situations shall be in accordance with the following table:
 
Population
Peak Flow
Under 750
4.0 times the average
Under 1000
3.9 times the average
Under 1750
3.8 times the average
Under 2500
3.6 times the average
Under 5000
3.3 times the average
Over 5000
The Engineer must be consulted
 
   (B)   Industrial or commercial sewage. The amount of sewage shall be fixed after consultation with the Engineer.
   (C)   Infiltration. An allowance of 1000 gallons per acre per day for the gross tributary area of the drainage basin shall be added to the above peak sanitary flows.