§ 51.03 EXTENSIONS OF WATER MAINS.
   (A)   (1)   Any property owner or developer desiring to extend the public water main for the benefit of his property may do so at his or her own expense.
      (2)   Minimum main size shall be four inches in diameter or larger where required by the master plan on file with the Village Clerk or where required by the Board of Trustees to serve the future growth in the vicinity of the extension.
   (B)   All construction shall be in accordance with the Standard Specifications for Water and Sewer Main Construction in Illinois, second Edition.
   (C)   Pipe to be used shall be Class 150 cast iron or 200 psi PVC pipe conforming to accepted current standards of ASITI 1784 (for schedule 40, 80 and 160 pipe, ASTM 0.2241 (SDR-DR) and No. 14 of the Sanitation Foundation (NSF) and be appropriately marked as specified by the foundation. Minimum acceptable pipe is one having standard dimension ratio of 21 (SDR-21) and Type 1 Grade 1 materials with a hydrostatic design stress of 2,000 psi for water at 23°C for a working pressure of 200 psi. Joints shall be of the rubber gasket type.
(Ord. passed 1-16-1979)