1144.07 APPLICATION REQUIREMENTS.
   An applicant proposing to construct a new tower must submit an improvement plan in accordance with Chapter 1109. In addition to meeting the requirements of Section 1109.01, the plan must include:
   (a)   The location of all existing facilities and towers owned or used by the applicant within the City and outside the City limits within a one-fourth mile radius. Provide the following information for each existing facility:
      (1)   Type and size of the tower and facilities at each location.
      (2)   The type and accessory equipment and/or building located at each site.
      (3)   The ground network and associated land lines utilized by each tower.
   (b)   The general location of planned future towers and facilities.
   (c)   For each specific tower location shown on the plan, there must be a schedule showing:
      (1)   Type and size of the tower and facility at each location.
      (2)   The type of accessory equipment located or proposed on each tower.
      (3)   Type, size and location of any support structure to be used by the tower for which the application is being submitted.
      (4)   The ground network and associated land lines, if any, utilized by each site.
      (5)   A site plan showing the parcel on which any existing tower is located.
      (6)   Detailed drawing of screening plan and related design standards.
   (d)   Copies of all certified mail announcements to all other owners of towers and tall structures must be attached to the application. See Section 1144.02 (d) herein.
   (e)   Notification from the FAA and local airport describing any requirements to be set forth on the tower and its location.
      (Ord. 75-97. Passed 6-5-97.)