(a) Water. Every mobile home park shall be served by an approved off- site water system.
(b) Fire Protection. For fire protection purposes, there shall be domestic water under adequate pressure in standard fire hydrants approved by the Village Administrator/Clark County Engineer, which hydrants shall be located within five hundred (500) feet of every mobile home space or lot within the mobile home park.
(c) Sanitary Sewers. Every mobile home park shall be connected to an approved off-site sanitary sewerage system.
(d) Storm Drainage. Adequate storm drainage for each mobile home lot shall be provided.
(e) Heating Fuel Supply. Fuel systems shall be installed and maintained in accordance with applicable state and local codes and regulations. All fuel storage containers, barrels, tanks, or cylinders and piping to the mobile homes shall be securely fastened in place and protected against physical damage.
(f) Natural Gas System. When natural gas piping systems are used, they shall be installed underground in accordance with applicable codes and regulations and public utility standards. Each mobile home space or lot provided with piped natural gas shall have an approved manual shutoff valve installed upstream of the gas outlet. The outlet shall be equipped with an approved method to prevent accidental discharge of gas when the outlet is not in use.