§ 51.46 PROHIBITED CONNECTIONS.
   (A)   No person shall make connection of roof downspouts, basement wall seepage or floor seepage, exterior foundation drains, areaway drains, or other surface runoff or groundwater to a building sewer or building drain which in turn is connected directly or indirectly to a public sanitary sewer. Any such connections which already exist on the effective date of this chapter shall be completely and permanently disconnected within sixty (60) days of the effective date of this chapter. The owner(s) of any building sewers having such connections, leaks or defects shall bear all costs incidental to removal of such sources. Pipes, sumps, and pumps for such sources of ground and surface water shall be separate from wastewater facilities. Removal of such sources of water without presence of separate facilities shall be evidence of drainage to public sanitary sewer.
   (B)   All building sewers shall be smoke tested through the wye branch at the public sewer connection, with public sewer tightly plugged off, after connections at both ends are made and after all pipe is properly bedded and backfilled at least to top of pipe and if backfill is completed, within two (2) weeks after completion of backfill. At time of test, any openings into the building drain inside the building shall be water trapped or plugged. Any leakage of smoke from building sewer or building drain and plumbing shall be located at test and repaired to stand repetition of smoke test without leakage. When smoke testing is completed, the temporary flow line plug shall be removed and a permanent watertight plug shall be placed in branch of test wye-branch and carefully backfilled by hand and tamped to at least six (6) inches above the top of the branch.
(Ord. 92-015, passed 12-14-92; Am. Ord. 2012-001, passed 1-9-12)