§ 153.42 ADDITIONS, INSERTIONS, DELETIONS AND CHANGES TO THE INTERNATIONAL RESIDENTIAL CODE.
   The following sections are hereby revised as follows:
   (A)   Chapter 1: Administrative.
      (1)   Section R-101.1. Insert "The Village of Elwood".
      (2)   Section R-108.2. See the Village of Elwood fee ordinance.
      (3)   Section R-113.4 is amended to read as follows:
         "Unless otherwise provided herein, any person who violates, disobeys, omits, neglects or refused to comply with, or who resists, the enforcement of any of the provisions of this Code, including provisions adopted by reference, or who refuses to remedy a violation of any such provisions or to remedy a hazard of fire, explosion, collapse, contagion or spread of infectious disease found to exist and duly ordered eliminated shall be fined not less than twenty-five and no/100 dollars ($25.00), nor more than seven hundred-fifty and no/100 dollars ($750.00), exclusive of court costs and administrative fees established by statute and the costs of prosecution for each offense, and each day upon which such violation continues shall constitute a separate offense."
      (4)   Section R-114.2. Insert "not less than twenty-five and no/100 dollars ($25.00) and not more than seven hundred-fifty and no/100 dollars ($750.00)/(96-03, 01-16-96)
      (5)   Section R-112. Delete the entire section and insert the following: The Village Board shall act as the Appeals Board.
   (B)   Chapter 2: Definitions. Add the following definition: Any home which has less than the required 10 foot setback shall be classified as a townhouse and comply with all requirements for a townhouse including sprinkler protection.
   (C)   Chapter 3: Building Planning.
      (1)   Section R-301.2:
         (1)   “Climatic Criteria is amended as follows;
            "Table 301.2(1) Climatic and Geographic Design Criteria is amended by inserting the following under the respective headings.
               Ground Snow Load - lbs. per square foot - 25
               Wind Speed - 75 mph (90 mph = 3 second gust)
               Topographical effects - YES
               Special Wind Region N/A
               Windborne Debris N/A
               Seismic Design Category - B
               Subject to Damage from weathering - Severe
               Frost line depth - 42" below grade
               Subject to Damage from termites -Moderate to heavy
               Decay - Slight to Moderate
               Winter Design Temperature for heating - -4 degrees
               Ice Barrier Underlayment - YES
               Flood Hazard - Per the Village of Elwood Flood Plain
               Map/Ordinance
               Air Freezing Index - 2000
               Mean Annual Temperature - 50 degrees
            Manual J Design Criteria
               Elevation               581 feet
               Latitude               41
               Winter heating               0
               Summer cooling            90 degrees
               Altitude correction factor         1%
               Indoor design temperature         72° F
               Design temperature cooling         75° F
               Heating temperature differential      (72)
               Cooling temperature differential      15
               Wind velocity heating            15
               Coincident wet bulb            74
               Daily range               M
               Winter humidity            50
               Summer differential            50
      (2)   Section and Table R302.6: Change the right column to indicate a one hour fire rated assembly for each row.
      (3)   Section R309.5: Garages - Fire Sprinklers. Clarification: Fire sprinklers are not required in One and Two Family Dwellings however if installed Table R302.1(2) and this section can be used.
      (4)   Section R313.2: One and Two Family dwellings automatic fire sprinkler systems. Delete the section in its entirety.
      (5)   Section R405.1. Add the following: All systems which discharge ground water through the use of pumps shall have a minimum of two sump pits each with a separate sump pump.
   (D)   Chapter 4: Foundations.
      (1)   Section R-402.1, R-402.1.1, and R-402.2.2. Wood Foundations are deleted in their entirety.
      (2)   Section R-403.1. Delete all references to wood footings.
   (E)   Chapter 8: Roof Coverings.
      (1)   Section R-908.3 is amended by adding to it the following:
         “Re-roofing over wood shakes shall not be allowed.”
   (F)   Chapter 21: Hydronic piping.
      (1)   Section M 2103.4. Add the following: The system shall be tested to the same criteria after the concrete or other covering has been installed.
   (G)   Chapters 25-32. These Chapters are deleted in their entirety.
   (H)   Chapter 44. Change the following referenced standards.
      ICC:
            Delete the International Zoning Code.
            Delete the references to the International Plumbing Code and insert the Illinois Plumbing Code.
            Delete the International Sewage Disposal Code.
            NFPA - The current edition of the NFPA standards shall be used.
      Appendices:   adopt the following Appendices: A, B, C, D, F, G, K, M, O.
(Ord. 789, passed 9-21-2005; Am. Ord. 1042, passed 3-18-2015; Am. Ord. 1043, passed 4-15-2015; Am. Ord. 1088, passed 3-7-2018)