§ 51.090 USER CHARGE FORMULA.
   (A)   The POTW is primarily flow dependent. Therefore, the following formula is used to calculate user charges.
 
Cu
=
Ct
×
Vu
Vt
 
   Where:
      Ct   =   Total operation and maintenance plus replacement (O&M+R) costs per unit of time.
      Cu   =   A user’s charge for O&M+R per unit of time.
      Vu   =   Volume contribution from a user per unit of time.
      Vt   =   Total volume contribution from all users per unit of time.
   (B)   In the event BOD, suspended solids, or other pollutant concentrations from a user exceed the range of concentration of these pollutants in normal domestic sewage, a surcharge added to the base charge (above) will be levied. The surcharge will be computed by the formula below.
Cs = (Bc(B) + Sc(S) + Pc(P)) Vu
   Where:
      Cs   =   A surcharge for wastewaters of excessive strength.
      Bc   =   O&M+R cost for treatment of a unit of biochemical oxygen demand (BOD).
      B   =   Concentration of BOD from a user above a base level.
      Sc   =   O&M+R cost for treatment of a unit of suspended solids.
      S   =   Concentration of SS from a user above a base level.
      Pc   =   O&M+R cost for treatment of a unit of any pollutant.
      P   =   Concentration of any pollutant from a user above a base level.
      Vu   =   Volume contribution from a user per unit of time.
   (C)   Any other pollutant which causes an increase in the cost of treatment will be assessed in a similar fashion.
 
Other Pollutant Rate
=
Total Cost to Treat Other Pollutant
Total Pounds of Other Pollutant
 
(Prior Code, § 16-6-1)