In order to guide development outside a Wetland District to prevent harm to wetlands inside the district, the following standards are established:
(A) No building, structure, street, road, alley, driveway parking area or paved surface shall be placed closer than 75 feet from the boundary of a Wetland District.
(B) No septic system shall be installed closer than 150 feet from the boundary of a Wetland District.
(C) The lowest ground floor elevation of all buildings or additions to existing buildings within 50 feet of the boundary of a Wetland District shall be at least two feet above the ordinary high water mark.
(D) No soil storage pile shall be placed nearer than 25 feet from the boundary of a Wetland District. Erosion from all soil storage piles placed within 200 feet of the boundary of a Wetland District shall be controlled by placing straw bales, filter fence or other effective containment barriers around the piles. Soil loss from any construction site within 200 feet of the district boundary shall be controlled by measures described in the U.S. Department of Agriculture Soil Conservation Service Field Office Technical Guide.
(E) No storm water runoff from a development shall be directed into a Wetland District except as provided in § 151.146(C)(4).
(1979 Code, § 151.117) (Ord. 4370, passed 7-20-1998) Penalty, see § 151.999