8-3D-1: PLUMBING CODE ADOPTED:
   A.   Codes Adopted: There is hereby adopted by reference, as if fully set out herein, those certain codes known as the International Plumbing Code, 2018 edition, prepared and published by the International Code Council and the most recently published edition of the State of Illinois Plumbing Code, being 77 Ill. Adm. Code 890, prepared and published by the Illinois Department of Public Health, together with the additions, insertions, deletions and changes hereinafter set forth, one copy which is available for inspection and is on file in the Office of the Village Clerk.
   B.   International Plumbing Code Amendments: The following additions, insertions, deletions and changes are hereby made to the International Plumbing Code, 2018 edition:
      1.   Section 101.1: Insert "Elk Grove Village".
      2.   Section 106.6.2: Insert "As may be established from time to time by the Mayor and Board of Trustees".
      3.   Section 106.6.3: Fee Refunds is hereby deleted in its entirety.
      4.   Section 108.4: Violation Penalties is hereby amended to read as follows:
108.4 Violation Penalties. Any person who shall violate any provision of this code or shall fail to comply with any of the requirements thereof or who shall erect, install, alter or repair plumbing work in violation of the approved construction documents or directive of the code official or of a permit or certificate issued under the provisions of this code shall be subject to the penalties as provided for by Title 8, Chapter 3, Article K of the Municipal Code.
      5.   Section 108.5: Insert "one hundred" and "five hundred" respectively.
      6.   Section 109 Means of Appeal is hereby deleted in its entirety.
      7.   Section 305.4.1 Sewer Depth is hereby deleted in its entirety.
      8.   Table 605.3: Water Service Pipe is hereby amended to permit only the following pipe materials for water service pipe:
         i. Copper or Copper Alloy Tubing Type K - ASTM B 75; ASTM B 88; ASTM B 251; ASTM B 447.
         ii. Ductile Iron Water Pipe - AWWA C151/A 21.51; AWWA C115/A 21.15.
      9.   Table 605.4 Water Distribution Pipe is hereby amended to permit only the following materials for water distribution pipe:
         i. Copper or Copper Alloy Pipe (Types K or L only) - ASTM B 42; ASTM B 302.
         ii. Copper or Copper Alloy Tubing (Types K or L only) - ASTM B 75; ASTM B 88; ASTM B 251; ASTM B 447.
         iii. Galvanized Steel Pipe - ASTM A 53.
      10.   Section 605.6 Flexible Water Connectors shall be amended by adding thereto the following final sentence:
Flexible water connectors shall not be permitted for the installation of water heaters.
   C.   State Plumbing Code Amendments: The following additions, insertions, deletions and changes are hereby made to the most recently published edition of the State of Illinois Plumbing Code:
      1.   Add new Section 890.1220 a) 11) as follows:
890.1220 a) 11) Water Heater Connection. Flexible water connectors shall not be permitted for the installation of water heaters.
      2.   Section 890. Appendix A, Table A. Approved Materials for Water Service Pipe is hereby amended to permit only the following pipe materials for water service pipe:
         i. Cast iron (Ductile Iron) - ASTM A 377-1984.
         ii. Copper/Copper Alloy Tubing Type K - ASTM B 88-1988.
      3.   Section 890. Appendix A, Table A. Approved Materials for Water Distribution Pipe is hereby amended to permit only the following pipe materials for water distribution pipe:
         i. Copper/Copper Alloy Pipe (Types K or L only) - ASTM B 42-1988: ASTM B 302-1988.
         ii. Copper/Copper Alloy Tubing (Types K or L only) - ASTM B 88-1988.
         iii. Galvanized Steel Pipe - ASTM A 53-1988; ASTM A 120-1984.
(Ord. 3597, 3-12-2019)
      4.   Pursuant to 17 Illinois administrative code 3730.307(c)(4) and subject to the Illinois plumbing code (77 Ill. adm. code 890) and the lawn irrigation contractor and lawn sprinkler system registration code (77 Ill. adm. code 892), all new plumbing fixtures and irrigation controllers installed after the effective date hereof shall bear the WaterSense label (as designated by the U.S. environmental protection agency WaterSense program), when such labeled fixtures are available.
(Ord. 3457, 7-19-2016)