(A) The light pattern shall be designed so that the lowest FC (foot candle) value at any point on the roadway surface will not be less than one-sixth the average value. For residential roadways, the average value shall be 0.2 FC. The lowest average value in commercial and industrial subdivisions shall be 0.2 FC; however, higher average values may be considered depending upon the usage and traffic in the area. In a new subdivision, the appropriate utility company will submit a lighting plan for review by the City Council.
(B) The plan will be submitted shortly after the adoption of the final subdivision plat and will be developed using a minimum average lighting value of 0.2 FC, inclusive of other ambient lighting, or a higher value if established by the City Council and the following guides.
(1) All intersections will be lighted.
(2) All cul-de-sacs will be lighted.
(3) Mid-block lights will be installed at approximately 250-foot intervals.