Sec. 15-1-8 Garages.
   (a)   Construction Standards.
      (1)   Detached Garages. New construction detached garages on concret slabs shall comply with the following standards when greater than two hundred (200) square feet and serve one and two family dwellings: Grade beam slabs are required for private, residential garages with a continuous floating slab of reinforced concrete and shall not be less than four (4) inches in thickness. Reinforcement shall be a minimum of six by six (6 x 6) inch, number ten (I 0) wire mesh. The slab shall be provided with a thickened edge all around, eight (8) inches wide and eight (8) inches below the top of the slab. (Exempted are "frost free footings" for detached residential accessory buildings) SPS 322, Wis. Adm. Code, shall not apply.
      (2)   Other Residential Detached Accessory Buildings. Concrete slabs, frost free footings, etc. are not required, but if they are installed they shall follow Subsection (b)(2) above and/or SPS 321, Wis. Adm. Code.
   (b)   Pole Buildings. Pole buildings shall be designed through structural analysis to meet the design standards of the zoning district in which it is located. These design standards shall also include architectural appearance and dimensional standards as required by zoning districts. No accessory building shall have a reflective finish on the roof or sides.
   (c)   Garages in Commercial/Industrial Districts. Garages or structures erected on parcels zoned commercial or industrial shall constructed as a commercial code-compliant building.