1365.06 GENERAL REQUIREMENTS FOR EXTERIOR STRUCTURE.
   (a)   In General. The exterior of a structure shall be maintained in good repair, structurally sound and sanitary, so as not to pose a threat to the public health, safety or welfare.
   (b)   Street Numbers. Each structure to which a street number has been assigned shall have such number displayed in a position easily observed and readable from the public right-of-way. All numbers shall be in numerals at least three inches (76 mm) high and one-half inch (13 mm) stroke.
   (c)   Structural Members. All structural members shall be maintained free from deterioration, and shall be capable of safely supporting the imposed dead and live loads.
   (d)   Foundation Walls. All foundation walls shall be maintained plumb and free from open cracks and breaks and shall be kept in such condition so as to prevent the entry of rats, pests or other animals.
   (e)   Exterior Walls. All exterior walls shall be free from holes, breaks and loose or rotting materials and shall be maintained weatherproof and properly surface-coated where required to prevent deterioration.
   (f)   Roofs; Gutters and Downspouts; Drainage. The roof and flashing shall be sound, tight and not have defects that admit rain. Gutters and downspouts shall be used to collect roof water drainage and shall be maintained in a tight, leak-proof condition adequate to prevent dampness or deterioration in the foundation, walls or interior portion of the structure. Roof water drainage shall not be discharged in a manner that creates a public or private nuisance.
   (g)   Overhang Extensions. All canopies, marquees, signs, metal awnings, stairways, fire escapes, standpipes, exhaust ducts and similar overhang extensions shall be maintained in good repair and be properly anchored so as to be kept in a safe and sound condition. When required, all exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather coating materials, such as paint or similar surface treatment.
   (h)   Chimneys and Towers. All chimneys, cooling towers, smokestacks and similar appurtenances shall be maintained structurally safe and sound and in good repair. All exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic applications of weather-coating materials, such as paint or similar surface treatment.
   (i)   Handrails and Guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition.