1113.11 LOT DRAINS.
   All lots shall have access to underground drainage in the forms of Class E conduit lot drains extending from the storm sewers or inlets to the right-of-way line. Acceptable Class E conduit for lot drains shall meet Ohio Department of Transportation Specifications: 706.01; 706.02; 706.03; 706.07; 706.08; 706.09; 707.33; 707.42;707.43; 707.44; 707.45; 707.51 and 707.52. If one of the above listed P.V.C. or polyethylene pipes is specified for lot drains, it shall be smooth wall, nonperforated, and P.V.C. pipe shall be schedule 40 or stronger. Lot drains shall carry only sump, percolated and air conditioner water. Lot drains shall not carry storm water, surface water, downspout water or septic system and sanitary system effluents. Storm, surface, roof and downspout waters will be drained to the street curb or to storm pipes designed for the purpose of outletting such waters.
(Ord. 2002-25. Passed 4-8-03.)