Provided, in addition to the requirements of § 11.06.090.020, that:
(A) They are driven or drilled wells located on ground higher than surrounding ground to assure positive drainage from the well (ARM § 36.15.602(6));
(B) They require no other structures (e.g., a well house (ARM § 36.15.602(6));
(C) Well casings are water tight to a distance of at least 25 feet below the ground surface and the well casing height is a minimum of two feet above the base flood elevation or capped with a watertight seal and vented two feet above the base flood elevation (ARM § 36.15.602(6));
(D) Water supply lines have a watertight seal where the lines enter the casing (ARM § 36.15.602(6));
(E) All pumps and electrical lines and equipment are either of the submersible type or are adequately flood proofed (ARM § 36.15.602(6)); and
(F) Check valves are installed on main water lines at wells and at all building entry locations (44 C.F.R. § 60.3 (a)(5); ARM § 36.15.602(6)).