§ 51.16 SPECIFICATIONS FOR INSTALLATION OF SEWER SYSTEMS IN OLD BUILDINGS.
   When and if it becomes necessary to install sewer systems in old buildings, the following specifications must be complied with:
   (A)   If property is under one ownership, a maximum of two separate buildings may be connected to a four-inch or six-inch sewer connection. When and if the ownership of these two buildings shall be divided, a separate connection must be provided for each building.
   (B)   If more than two buildings are under one ownership and it is desired to drain the waste from these buildings to the sanitary sewer at a single point, a private sewer must be installed at the property owner’s expense. The private sewer must be built in accordance with county specifications for sanitary sewers. The property owner must also obtain and record a permanent easement for the maintenance and operation of such private sewer. The property owner shall be responsible for the operation and maintenance of such private sewer.
(Ord. passed 9-9-08)