§ 15.10.915 ON-SITE IMPROVEMENTS REQUIRED.
   Improvements to be installed by each subdivider shall include the following:
   A.   Curb, gutter, sidewalks and walkways (for parking bays, where required), including those on the subdivision's side of streets bordering upon the boundaries of the subdivision.
   B.   Water lines, gas, electric, and other utility services to serve each lot and the stub to back of curb in front or to lot line in rear.
   C.   Fire hydrants, including gate valves for same, size and location to be approved by Fire Chief.
   D.   Sanitary sewers and laterals to serve each lot and stubs to back of curb, prior to paving.
   E.   Storm sewers, drains, and channel improvements.
   F.   Slope planting, silt basins, or other form of erosion control.
   G.   Paved streets, including those bordering upon the boundary of the subdivision, to the center line of the full proposed street width. Half streets shall be allowed only when, in the opinion of the Commission, there is no practical alternative thereto.
   H.   Street lights, complete, including electroliers, conduits, tunnels, and other necessary structures.
   I.   Street trees, as recommended by Parks Superintendent.
   J.   Street nameplate signs, including posts and hardware, at location approved by the City Engineer to standard City specifications.
   K.   Stop signs and other traffic control signs and signals required by the Standards Committee after recommendation of the Chief of Police.
   L.   Fire alarm call boxes to be located as approved by the Fire Chief.
('65 Code, § 31-124) (Ord. No. CS-622 § 1 (part))