The city authorizes the placement of manufactured homes in residential zones within the city if such manufactured homes comply with the following conditions.
(A) Manufactured homes shall comply with all zoning regulations for the zone in which they are located.
(B) A building permit and any other required permits shall be obtained for manufactured homes.
(C) No manufactured home located within an area platted after 1950 or located within an R-1 Zoning District shall have a building width of less than 24 feet at its narrowest point.
(D) No manufactured home located within an area platted before 1950 or located within an R-2 Zoning District shall have a building width of less than 24 feet at its narrowest point.
(E) Additionally, as to foundations, the following shall apply:
(1) Manufactured homes shall be placed on permanent foundations;
(2) Consisting of a cement slab or cement exterior foundations walls;
(3) Which otherwise comply with the Uniform Building Code (as between this chapter and the Uniform Building Code, the more restrictive shall apply);
(4) Which are solid for the complete perimeter of the house;
(5) Consist of stone or block with wet joint mortar or interlocking blocks;
(6) Plans and specifications must be those supplied by the manufacturer of the home; and
(7) Must be submitted to the city for approval prior to commencing construction.
(F) As to roofs, manufactured homes shall have a roof which is:
(1) Manufacturer-engineered;
(2) Manufacturer-approved;
(3) Pitched; and
(4) Have eaves of not less than six inches.
(G) Manufactured homes shall have a minimum floor area of 720 square feet.
(H) All hitches and wheels must be removed.
(Prior Code, § 13.90) (Ord. 2013-4, passed 11-12-2013)