(a) Grease, oil and sand interceptors shall be provided when in the opinion of the Safety-Service Director, they are necessary for the proper handling of liquid wastes containing grease in excessive amounts, or any flammable wastes, sand and other harmful ingredients, except that such interceptors shall not be required for private living quarters or dwelling units. All interceptors shall be located as to be readily and easily accessible for cleaning and inspection.
(b) Grease and oil interceptors shall be constructed of impervious materials capable of withstanding abrupt and extreme changes in temperature. They shall be of substantial construction, watertight and equipped with easily removable covers which, when bolted in place, shall be gastight and watertight.
(c) Where installed, all grease, oil and sand interceptors shall be maintained by the owner at his expense, in continuous efficient operation at all times.