APPENDIX B: R-2 DISTRICT REQUIREMENTS
R-2 District Requirements
Lot Requirements
Yard Requirements
Total
Any Unit with
Min. Lot Area Sq. Ft. per Unit
Min. Lot Width
Max. Lot Coverage
Yards Front/Sides
Rear
Interior
Corner
R-2 District Requirements
Lot Requirements
Yard Requirements
Total
Any Unit with
Min. Lot Area Sq. Ft. per Unit
Min. Lot Width
Max. Lot Coverage
Yards Front/Sides
Rear
Interior
Corner
None
20,000
100 ft.
110 ft.
25%
30 ft./10% (max. 10 ft.)
35 ft.
Public water or sewer
10,000
90 ft.
100 ft.
30%
30 ft./10% (max. 10 ft.)
25 ft.
Public water or sewer
10,000
90 ft.
100 ft.
30%
30 ft./10% (max. 10 ft.)
25 ft.
Single-family water and sewer
5,000
50 ft
65 ft.
40%
25 ft./10% (max. 10 ft.)
25 ft.
Semi-detached water and sewer
3,000
30 ft.
45 ft.
55%
25 ft./10% (max. 10 ft.)
25 ft.
 
   (A)   On a corner lot, the side yard abutting the street shall be the same as the depth of the required front yard.
   (B)   No building shall exceed two and one-half stories or 35 feet in height unless additional yard areas are provided. Front yards must be increased by five feet for each story over two and side and rear yards must be increased by two and one-half feet for each story over two.
   (C)   Accessory structure regulations.
      (1)   Setback requirements:
         (a)   Rear yard: five feet; and
         (b)   Side yard: one and one-half feet.
      (2)   Height limitations: maximum height: one story (maximum 20 feet).
      (3)   Prohibited: in front yard or on a side yard of a corner lot (only side yard abutting other street).
(Prior Code, Ch. 27, Attachment 2) (Ord. 293, passed 4-20-1992, § 7.3; Ord. 302, passed 10-18-1993, § 2; Ord. 313, passed 6-5-1995, § 2; Ord. 323, passed 7-6-1998; Ord. 3-2009, passed 1-4-2010, § 1)