§ 91.058 INSTALLATION STANDARDS FOR EXTERIOR FURNACES.
   The following are the standards for the installation of any exterior furnace which shall be in addition to any recommended installation requirements:
   (A)   Installation upon a nominal six inch thick permanent, reinforced concrete pad in such dimension so as to allow a minimum of six inches of exposed surface area along the perimeter of the pad;
   (B)   (1)   The height of a smokestack must be a minimum height exceeding four feet in elevation higher than any adjacent structure, building or wall that is within 100 feet of the location of the exterior furnace.
      (2)   The smokestack must be securely anchored so as to eliminate the possibility of collapse.
      (3)   The location of the smokestack must be at least one and one-half times its height from any structure located on any adjacent premises; and
   (C)   (1)   Installation of any electrical or plumbing apparatus or device used in connection with the operation of an exterior furnace shall be in conformity with all applicable electrical and plumbing codes.
      (2)   In the absence of such code, in conformity with the manufacturer’s installation specifications.
(Prior Code, Ch. 10, § 404) (Ord. 2-2009, passed 6-15-2009, § IV) Penalty, see § 91.999