§ 3. SANITARY AND COMBINED SEWER PIPE TYPES AND FILL HEIGHTS.
Diameter
(Inches)
Vitrified Clay Pipe
Plain Concrete Pipe
Cast Iron Pipe
Extra Strength
(In Feet)
Standard Strength
(In Feet)
Extra Strength
(In Feet)
Standard Strength
Heavy Strength
Extra- Heavy Strength
Standard Bedding
B1 Bedding
Standard Bedding
B1 Bedding
Standard Bedding
B1 Bedding
Standard Bedding
(In Feet)
Diameter
(Inches)
Vitrified Clay Pipe
Plain Concrete Pipe
Cast Iron Pipe
Extra Strength
(In Feet)
Standard Strength
(In Feet)
Extra Strength
(In Feet)
Standard Strength
Heavy Strength
Extra- Heavy Strength
Standard Bedding
B1 Bedding
Standard Bedding
B1 Bedding
Standard Bedding
B1 Bedding
Standard Bedding
(In Feet)
4
30
27
6
21
30
8
12
16
8
27
30
18
27
30
10
22
15
22
12
20
13
28
20
15
12
26
18
24
21
11
23
18
37
24
37
22
27
18
22
36
50
30
33
-
-
-
-
36
39
36
 
   1.   No sanitary or combined sewer pipe less than 15 inches in diameter shall be installed under a fill height of greater than 30 feet.
   2.   Reinforced concrete pipe may also be used for sanitary and combined sewers. See current RDI-001 for fill heights.
As per § 157.102 of this chapter.
(1984 Code, Ch. 157, App. C, § 3) (Ord. O-86-78, passed 8-17-1978)