148.05 SUBMITTAL REQUIREMENTS.
1.   Design Review Submittal Requirements: Submittals should be consistent with the intent to generally review the scope and intent of the proposed project.
2.   Submittals shall comply with the site plan submittal requirements described in paragraphs 8(A), 8(B), and 8(C) of Section 165.33, PUD Planned Unit Development District and Section 165.52 Site Plan Review of Chapter 165, Zoning Regulations. Site plan submittals for design review shall also include the following:
   A.   Architectural Elevations:
      (1)   Show all building elevations visible from public rights-of-way, public parking areas, or sidewalks.
      (2)   Note all finish materials on drawings and provide color samples.
      (3)   Dimension building heights from finish grade.
      (4)   Dimensions of all exterior walls and fences, including heights.
      (5)   Show building sign location, types, and size of signs.
      (6)   Show location of mechanical equipment, roof equipment, electrical transformers, and solar panels, including means of screening roof equipment.
   B.   Site Sections and Profiles: Submit two (2) site sections to illustrate the following information:
      (1)   Scale of building(s) and site.
      (2)   Building(s) location and relationship to other on and off-site elements.
   C.   Signage Plans:
      (1)   Freestanding ground signs: Submit design drawings (plans, elevations, and section) illustrating the following information:
         (a)   Location.
         (b)   Size and shape.
         (c)   Materials and colors.
         (d)   Sign copy to include size of letters and type style.
      (2)   Building wall mounted signs: Submit architectural elevations illustrating the following information:
         (a)   Location on building.
         (b)   Size and shape.
         (c)   Materials and colors.
         (d)   Sign copy to include size of letters and type style.
   D.   Lighting Plans: Submit a profile of all proposed building mounted lights and site lights to include the following information:
      (1)   Fixture locations.
      (2)   Type and size of fixture.
      (3)   Mounting heights and ground mounting details.
      (4)   Fixture specifications as to lamp type, wattage, photometrics, etc.
      (5)   Pole and fixture materials and colors.
   E.   Site Amenities Information: Site amenities include site furniture and other site features not specifically a part or direct extension of the building architecture. Elements such as benches, litter receptacles, plant containers, flagpoles, drinking and decorative fountains, seat walls, retaining walls, architectural screen walls, and site art such as sculpture are examples of site amenities. Submit design drawings, manufacturer’s literature, photographs or other information sufficient in detail to provide the following information:
      (1)   Site location of features.
      (2)   Type, size, style, or appearance of each element.
      (3)   Material types, colors, and finishes.
   F.   Additional Information:
      (1)   Additional information, drawings, or other materials necessary to describe the project may be requested by the Design Review Committee.
      (2)   The applicant may include additional information or materials such as sketches, videos, models, or photos, if they help explain the proposal.
      (3)   The Design Review Committee may waive all or part of the submittal requirements if the nature of the project warrants.