§ 150.03 INTERNATIONAL PLUMBING CODE.
   That certain code entitled International Plumbing Code, 2006 Edition, along with Appendices, E and F is hereby adopted as the Plumbing Code of the Town of Colorado City and made part of this chapter the same as though that code was specifically set forth in full herein, with the following revisions:
   (A)   Section 603.1 Size of Water Service Pipe shall be amended to read “Water service pipe sizing tables found in the Uniform Plumbing Code is an acceptable alternate method to determine size;”
   (B)   Section 311.1 Toilet Facilities is deleted in its entirety;
   (C)   Add Section 412.5 Public Toilet Rooms. All public toilet rooms shall be equipped with at least one floor drain;
   (D)   Section 606.2 Location of Shutoff Valves shall be amended by deleting item #2;
   (E)   Section 701.2 Sewer Required shall be amended to add “within 300 feet of the property line” after where available;
   (F)   Section 715.1 Sewage Backflow shall be deleted in its entirety and replaced with the following: All structures connected to a public sewer system shall be protected by an approved backwater valve;
   (G)   Section 904.6 Extension Through the Wall shall have the following sentence added at the end of the paragraph: Vents extending through the wall shall terminate not less than 12 inches from the wall with an elbow pointing downward;
   (H)   Section 905.4 Vertical Rise of Vent Exception shall be revised to add “floor drains and floor sink installations; and
   (I)   Section 1108 Combined Sanitary and Storm System is hereby deleted in its entirety and replaced with “Combining storm and sanitary drainage prohibited. The combining of sanitary and storm drainage systems is prohibited.”
(Ord. 2007-4, passed 7-16-2007)