11-2-2-5: FUEL OIL DISTRIBUTION SYSTEMS:
   (A)   Distribution systems shall be installed and maintained in accordance with applicable codes and regulations governing such systems. Piping installed belowground shall have a minimum earth cover of eighteen inches (18").
   (B)   All piping from outside fuel storage tanks or cylinders to mobile homes shall be permanently installed and securely fastened in place.
   (C)   All fuel oil storage tanks or cylinders should be installed underground and shall not be located inside or beneath any mobile home or accessory structure, or less than five feet (5') from any mobile home exit.
   (D)   Every tank shall be vented by a vent not less than one and one-fourth inches (11/4") iron pipe size, so designed and installed to prevent entrance of rain or debris.
   (E)   A shutoff valve located immediately adjacent to the gravity feed connection of a tank shall be installed in the supply line to the mobile home.
   (F)   Fuel oil connectors from the tank to the mobile home shall be brass or copper tubing or approved flexible metal hose, not smaller than three-eighths inch (3/8") iron pipe size or tubing, and shall be protected from physical damage. Aluminum tubing shall not be used.
   (G)   Valves and connectors shall be listed standard fittings maintained liquid tight to prevent spillage of fuel oil on this ground. (Ord. 45, 3-19-1973)