§ 153.080 BURIED, SUSPENDED UTILITY TRANSMISSION LINES.
   In addition to the requirements of § 153.076:
   (A)   Suspended utility transmission lines are designed such that the lowest point of the suspended line is at least six feet higher than the base flood elevation;
   (B)   Towers and other appurtenant structures are designed and placed to withstand and offer minimal obstruction to flood flows;
   (C)   Alternatives such as alternative routes, directional drilling, and aerial crossings are considered when technically feasible; and
   (D)   Utility transmission lines carrying toxic or flammable materials are buried to a depth of at least twice the calculated maximum scour depth determined by an engineer for the base flood.
(Prior Code, § 11-2(9.6))
Statutory reference:
   Buried and suspended utility transmission lines regulations in the floodway, see ARM § 36.15.602(4)