13-144-030  Heavy timber.
   Heavy timber members, sawn or glue-laminated, used in Type III-A construction shall be stress-grade timbers identified as to grade and strength by approved manufacturing, testing, or inspection agencies or bureaus. All structural members shall have the minimum dimensions specified in Section 13-60-050 for Type III-A construction and shall be designed, fabricated and installed in accordance with ANSI/NFoPA NDS-91 and American Institute of Timber Construction standard ANSI/AITC A190.1-92.