1480.02   REGULATIONS.
   The following version of the 2018 edition of the International Property Maintenance Code is hereby adopted:
   (a)   Chapter 1 Administration.
      (1)   Section 101 General.
101.1 Title. These regulations shall be known as the Centerville Property Maintenance Code, hereinafter referred to as "this code."
101.2 Scope. The provisions of this code shall apply to all existing residential and nonresidential structures and all existing premises and constitute minimum requirements and standards for premises, structures, equipment and facilities for light, ventilation, space, heating, sanitation, protection from the elements, a reasonable level of safety from fire and other hazards, and for a reasonable level of sanitary maintenance; the responsibility of owners, an owner's authorized agent, operators and occupants; the occupancy of existing structures and premises, and for administration, enforcement and penalties.
101.3 Intent. This code shall be construed to secure its expressed intent, which is to ensure public health, safety and welfare insofar as they are affected by the continued occupancy and maintenance of structures and premises.
101.4 Severability. If a section, subsection, sentence, clause or phrase of this code is, for any reason, held to be unconstitutional, such decision shall not affect the validity of the remaining portions of this code.
      (2)   Section 102 Applicability.
102.1 General. Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall govern. Where differences occur between provisions of this code and the referenced standards, the provisions of this code shall apply. Where, in a specific case, different sections of this code specify different requirements, the most restrictive shall govern.
102.2 Maintenance. Equipment, systems, devices and safe-guards required by this code or a previous regulation or code under which the structure or premises was constructed, altered or repaired shall be maintained in good working order. An owner, owner's authorized agent, operator or occupant shall not cause any service, facility, equipment or utility that is required under this section to be removed from, shut off from or discontinued for any occupied dwelling, except for such temporary interruption as necessary while repairs or alterations are in progress. The requirements of this code are not intended to provide the basis for removal or abrogation of fire protection and safety systems and devices in existing structures. Except as otherwise specified herein, the owner or the owner's authorized agent shall be responsible for the maintenance of buildings, structures and premises.
102.3 Application of other codes. Repairs, additions or alterations to a structure, or changes of occupancy, shall be done in accordance with the procedures and provisions of the Ohio Basic Building Code, Ohio Revised Code, Residential Code of Ohio, and the National Electric Code as amended by the Centerville Municipal Code and the Centerville Zoning Code.
102.4 Existing remedies. The provisions in this code shall not be construed to abolish or impair existing remedies of the jurisdiction or its officers or agencies relating to the removal or demolition of any structure which is dangerous, unsafe and unsanitary.
102.5 Workmanship. Repairs, maintenance work, alterations or installations that are caused directly or indirectly by the enforcement of this code shall be executed and installed in a workmanlike manner and installed in accordance with the manufacturer's instructions.
102.6 Historic buildings. The provisions of this code shall be mandatory for existing buildings or structures designated as historic buildings when such buildings or structures are judged by the code official to be safe and in the public interest of health, safety and welfare.
102.7 Requirements not covered by code. Requirements necessary for the strength, stability or proper operation of an existing fixture, structure or equipment, or for the public safety, health and general welfare, not specifically covered by this code, shall be determined by the code official.
102.8 Application of references. References to chapter or section numbers, or to provisions not specifically identified by number, shall be construed to refer to such chapter, section or provision of this code.
102.09 Other laws. The provisions of this code shall not be deemed to nullify any provisions of local, state or federal law.
      (3)   Section 103 Code Enforcement Department.
103.1 General. The Code Enforcement Department is hereby created and the executive official in charge thereof shall be known as the code official.
103.2 Appointment. The code official shall be appointed by the City Manager and shall serve at the will of the City Manager.
103.3 Deputies. In accordance with the prescribed procedures of this jurisdiction and with the concurrence of the appointing authority, the code official shall have the authority to appoint a deputy code official, other related technical officers, inspectors and other employees. Such employees shall have powers as delegated by the code official.
103.4 Liability. The liability of the code official, officer or employee charged with the enforcement of this code, while acting for the jurisdiction, shall be governed by the provisions of Ohio R.C. Chapter 2744.
      (4)   Section 104 Duties and Powers of the Code Official.
104.1 General. The code official is hereby authorized and directed to enforce the provisions of this code. The code official shall have the authority to render interpretations of this code and to adopt policies and procedures in order to clarify the application of its provisions. Such interpretations, policies and procedures shall be in compliance with the intent and purpose of this code. Such policies and procedures shall not have the effect of waiving requirements specifically provided for in this code.
104.2 Inspections. The code official shall make all of the required inspections, or shall accept reports of inspection by approved agencies or individuals. All reports of such inspections shall be in writing and be certified by a responsible officer of such approved agency or by the responsible individual. The code official is authorized to engage such expert opinion as deemed necessary to report upon unusual technical issues that arise, subject to the approval of the appointing authority.
104.3 Right of entry. Where it is necessary to make an inspection to enforce the provisions of this code, or whenever the code official has reasonable cause to believe that there exists in a structure or upon a premises a condition in violation of this code, the code official is authorized to enter the structure or premises at reasonable times to inspect or perform the duties imposed by this code, provided that if such structure or premises is occupied the code official shall present credentials to the occupant and request entry. If such structure or premises is unoccupied, the code official shall first make a reasonable effort to locate the owner, owner's authorized agent or other person having charge or control of the structure or premises and request entry. If entry is refused, the code official shall have recourse to the remedies provided by law to secure entry.
104.4 Identification. The code official shall carry proper identification when inspecting structures or premises in the performance of duties under this code.
104.5 Notices and orders. The code official shall issue all necessary notices or orders to ensure compliance with this code.
104.6 Department records. The code official shall keep official records of all business and activities of the department specified in the provisions of this code in accordance with the records retention policy of the City.
      (5)   Section 105 Approval.
105.1 Modifications. Whenever there are practical difficulties involved in carrying out the provisions of this code, the code official shall have the authority to grant modifications for individual cases upon application of the owner or owner's representative, provided the code official shall first find that special individual reason makes the strict letter of this code impractical and the modification is in compliance with the intent and purpose of this code and that such modification does not lessen health, life and fire safety requirements. The details of action granting modifications shall be recorded and entered in the department files.
105.2 Alternative materials, design and methods of construction and equipment. The provisions of this code are not intended to prevent the installation of any material or to prohibit any design or method of construction not specifically prescribed by this code, provided that any such alternative has been approved. An alternative material, design or method of construction shall be approved where the code official finds that the proposed design is satisfactory and complies with the intent of the provisions of this code, and that the material, method or work offered is, for the purpose intended, at least the equivalent of that prescribed in this code in quality, strength, effectiveness, fire resistance, durability and safety. Where the alternative material, design or method of construction is not approved, the code official shall respond in writing, stating the reasons why the alternative was not approved.
105.3 Required testing. Whenever there is insufficient evidence of compliance with the provisions of this code, or evidence that a material or method does not conform to the requirements of this code, or in order to substantiate claims for alternative materials or methods, the code official shall have the authority to require tests to be made as evidence of compliance at no expense to the jurisdiction.
   105.3.1 Test methods. Test methods shall be as specified in this code or by other recognized test standards. In the absence of recognized and accepted test methods, the code official shall be permitted to approve appropriate testing procedures performed by an approved agency.
   105.3.2 Test reports. Reports of tests shall be retained by the code official for the period required for retention of public records.
105.4 Used material and equipment. The use of used materials which meet the requirements of this code for new materials is permitted. Materials, equipment and devices shall not be reused unless such elements are in good repair or have been reconditioned and tested when necessary, placed in good and proper working condition and approved by the code official.
105.5 Approved materials and equipment. Materials, equipment and devices approved by the code official shall be constructed and installed in accordance with such approval.
105.6 Research reports. Supporting data, where necessary to assist in the approval of materials or assemblies not specifically provided for in this code, shall consist of valid research reports from approved sources.
      (6)   Section 106 Violations.
106.1 Unlawful acts. It shall be unlawful for a person, firm or corporation to be in conflict with or in violation of any of the provisions of this code.
106.2 Notice of violation. The code official shall serve a notice of violation or order in accordance with Section 107.
106.3 Prosecution of violation. Any person failing to comply with a notice of violation or order served in accordance with Section 107 shall be deemed guilty of a misdemeanor of the fourth degree and shall not be fined more than two hundred and fifty dollars ($250.00) or imprisoned not more than thirty days, or both, and the violation shall be deemed a strict liability offense. If the notice of violation is not complied with, the code official shall institute the appropriate proceeding at law or in equity to restrain, correct or abate such violation, or to require the removal or termination of the unlawful occupancy of the structure in violation of the provisions of this code or of the order or direction made pursuant thereto. Any action taken by the authority having jurisdiction on such premises shall be charged against the real estate upon which the structure is located and shall be certified to the County Auditor for collection, the same as other taxes and assessments are collected.
106.4 Violation penalties. Whoever violates any provision of this Code is guilty of a misdemeanor of the fourth degree and shall not be fined more than two hundred fifty dollars ($250.00) or imprisoned not more than thirty days, or both, for each offense and the violation shall be deemed a strict liability offense. An offense shall be deemed committed each day during or on which a violation occurs or continues.
106.5 Abatement of violation. The imposition of the penalties herein prescribed shall not preclude the legal officer of the jurisdiction from instituting appropriate action to restrain, correct or abate a violation, or to prevent illegal occupancy of a building, structure or premises, or to stop an illegal act, conduct, business or utilization of the building, structure or premises.
106.6 Informal Resolution of Violation. The code official may, at his or her discretion, attempt to informally resolve violations or suspected violations of this Code without issuing the notices and orders in the manner prescribed below. The code official shall be encouraged to utilize this procedure to the extent practical to achieve compliance with this Code.
106.7 Repeat Violators. For the second violation of the same general character occurring not sooner than twenty (20) days and not later than two (2) years after the first violation, the notice provided for in Section 107.2 may be omitted and a violation notice that specifies that the violation shall be corrected within twenty-four hours after service of the notice of violation, served pursuant to Section 107.3, may be issued. If the violation is not corrected by the specified compliance date, appropriate action or proceeding may be instituted in a court of proper jurisdiction. For the third violation of the same general character occurring not sooner than twenty (20) days and not later than two (2) years after the first violation, appropriate action or proceeding may be instituted immediately in a court of proper jurisdiction without notification to the property owner.
      (7)   Section 107 Notices and Orders.
107.1 Notice to person responsible. Whenever the code official determines that there has been a violation of this code or has grounds to believe that a violation has occurred, notice shall be given in the manner prescribed in Sections 107.2 and 107.3 to the person responsible for the violation as specified in this code. Notices for condemnation procedures shall also comply with Section 108.3.
107.2 Form. Such notice prescribed in Section 107.1 shall be in accordance with all of the following:
   1.   Be in writing.
   2.   Include a description of the real estate sufficient for identification.
   3.   Include a statement of the violation or violations and why the notice is being issued.
   4.   Include a correction order allowing a reasonable time to make the repairs and improvements required to bring the dwelling unit or structure into compliance with the provisions of this code.
   5.   Inform the property owner of the right to appeal to the Centerville Planning Commission. If a property owner desires such an appeal, a notice of appeal must be filed with the Clerk of Council within fifteen (15) days from the receipt of the notice prescribed in Section 107.1.
   6.   When applicable, include a statement of the right to file a lien in accordance with Section 106.3.
107.3 Method of service. Such notice shall be deemed to be properly served if a copy thereof is:
   1.   Delivered personally;
   2.   Sent by certified or first-class mail addressed to the last known address; or
   3.   A copy thereof shall be posted in a conspicuous place in or about the structure affected by such notice.
107.4 Unauthorized tampering. Signs, tags or seals posted or affixed by the code official shall not be mutilated, destroyed or tampered with, or removed without authorization from the code official.
107.5 Penalties. Penalties for noncompliance with orders and notices shall be as set forth in Section 106.4.
107.6 Transfer of ownership. It shall be unlawful for the owner of any dwelling unit or structure who has received a compliance order or upon whom a notice of violation has been served to sell, transfer, mortgage, lease or otherwise dispose of such dwelling unit or structure to another until the provisions of the compliance order or notice of violation have been complied with, or until such owner shall first furnish the grantee, transferee, mortgagee or lessee a true copy of any compliance order or notice of violation issued by the code official and shall furnish to the code official a signed and notarized statement from the grantee, transferee, mortgagee or lessee, acknowledging the receipt of such compliance order or notice of violation and fully accepting the responsibility without condition for making the corrections or repairs required by such compliance order or notice of violation.
      (8)   Section 108 Unsafe Structures and Equipment.
108.1 General. When a structure or equipment is found by the code official to be unsafe, or when a structure is found unfit for human occupancy, or is found unlawful, such structure shall be condemned pursuant to the provisions of this code.
   108.1.1 Unsafe structures. An unsafe structure is one that is found to be dangerous to the life, health, property or safety of the public or the occupants of the structure by not providing minimum safeguards to protect or warn occupants in the event of fire, or because such structure contains unsafe equipment or is so damaged, decayed, dilapidated, structurally unsafe or of such faulty construction or unstable foundation, that partial or complete collapse is possible.
   108.1.2 Unsafe equipment. Unsafe equipment includes any boiler, heating equipment, elevator, moving stairway, electrical wiring or device, flammable liquid containers or other equipment on the premises or within the structure which is in such disrepair or condition that such equipment is a hazard to life, health, property or safety of the public or occupants of the premises or structure.
   108.1.3 Structure unfit for human occupancy. A structure is unfit for human occupancy whenever the code official finds that such structure is unsafe, unlawful or, because of the degree to which the structure is in disrepair or lacks maintenance, is insanitary, vermin or rat infested, contains filth and contamination, or lacks ventilation, illumination, sanitary or heating facilities or other essential equipment required by this code, or because the location of the structure constitutes a hazard to the occupants of the structure or to the public. The structure must have water, electricity and gas (where applicable) service.
   108.1.4 Unlawful structure. An unlawful structure is one found in whole or in part to be occupied by more persons than permitted under this code, or was erected, altered or occupied contrary to law.
   108.1.5 Dangerous structure or premises. For the purpose of this code, any structure or premises that has any or all of the conditions or defects described below shall be considered dangerous:
      1.   Any door, aisle, passageway, stairway, exit or other means of egress that does not conform to the approved building or fire code of the jurisdiction as related to the requirements for existing buildings.
      2.   The walking surface of any aisle, passageway, stairway, exit or other means of egress is so warped, worn loose, torn or otherwise unsafe as to not provide safe and adequate means of egress.
      3.   Any portion of a building, structure or appurtenance that has been damaged by fire, earthquake, wind, flood, deterioration, neglect, abandonment, vandalism or by any other cause to such an extent that it is likely to partially or completely collapse, or to become detached or dislodged.
      4.   Any portion of a building, or any member, appurtenance or ornamentation on the exterior thereof that is not of sufficient strength or stability, or is not so anchored, attached or fastened in place so as to be capable of resisting natural or artificial loads of one and one-half the original designed value.
      5.   The building or structure, or part of the building or structure, because of dilapidation, deterioration, decay, faulty construction, the removal or movement of some portion of the ground necessary for the support, or for any other reason, is likely to partially or completely collapse, or some portion of the foundation or underpinning of the building or structure is likely to fail or give way.
      6.   The building or structure, or any portion thereof, is clearly unsafe for its use and occupancy.
      7.   The building or structure is neglected, damaged, dilapidated, unsecured or abandoned so as to become an attractive nuisance to children who might play in the building or structure to their danger, becomes a harbor for vagrants, criminals or immoral persons, or enables persons to resort to the building or structure for committing a nuisance or an unlawful act.
      8.   Any building or structure has been constructed, exists or is maintained in violation of any specific requirement or prohibition applicable to such building or structure provided by the approved building or fire code of the jurisdiction, or of any law or ordinance to such an extent as to present either a substantial risk of fire, building collapse or any other threat to life and safety.
      9.   A building or structure, used or intended to be used for dwelling purposes, because of inadequate maintenance, dilapidation, decay, damage, faulty construction or arrangement, inadequate light, ventilation, mechanical or plumbing system, or otherwise, is determined by the code official to be unsanitary, unfit for human habitation or in such a condition that is likely to cause sickness or disease.
      10.   Any building or structure, because of a lack of sufficient or proper fire-resistance-rated construction, fire protection systems, electrical system, fuel connections, mechanical system, plumbing system or other cause, is determined by the code official to be a threat to life or health.
      11.   Any portion of a building remains on a site after the demolition or destruction of the building or structure or whenever any building or structure is abandoned so as to constitute such building or portion thereof as an attractive nuisance or hazard to the public.
108.2 Closing of vacant structures. If the structure is vacant and unfit for human habitation and occupancy, and is not in danger of structural collapse, the code official is authorized to post a placard of condemnation on the premises and order the structure closed up so as not to be an attractive nuisance. Upon failure of the owner to close up the premises within the time specified in the order, the code official shall cause the premises to be closed and secured through any available public agency or by contract or arrangement by private persons and the cost thereof shall be charged against the real estate upon which the structure is located and shall be a lien upon such real estate and shall be collected by any other legal resource.
   108.2.1 Authority to disconnect service utilities. The code official shall have the authority to authorize disconnection of utility service to the building, structure or system regulated by this code and the referenced codes and standards set forth in Section 102.7 in case of emergency where necessary to eliminate an immediate hazard to life or property or when such utility connection has been made without approval. The code official shall notify the serving utility and, whenever possible, the owner and occupant of the building, structure or service system of the decision to disconnect prior to taking such action. If not notified prior to disconnection the owner or occupant of the building structure or service system shall be notified in writing as soon as practical thereafter.
108.3 Notice. Whenever the code official has condemned a structure or equipment under the provisions of this section, notice shall be posted in a conspicuous place in or about the structure affected by such notice and served on the owner or the person or persons responsible for the structure or equipment in accordance with Section 107.3. If the notice pertains to equipment, it shall also be placed on the condemned equipment. The notice shall be in the form prescribed in Section 107.2.
108.4 Placarding. Upon failure of the owner or person responsible to comply with the notice provisions within the time given, the code official shall post on the premises or on defective equipment a placard bearing the word "Condemned" and a statement of the penalties provided for occupying the premises, operating the equipment or removing the placard.
   108.4.1 Placard removal. The code official shall remove the condemnation placard whenever the defect or defects upon which the condemnation and placarding action were based have been eliminated. Any person who defaces or removes a condemnation placard without the approval of the code official shall be subject to the penalties provided by this code.
108.5 Prohibited occupancy. Any occupied structure condemned and placarded by the code official shall be vacated as ordered by the code official. Any person who shall occupy a placarded premises or shall operate placarded equipment, and any owner or any person responsible for the premises who shall let anyone occupy a placarded premises or operate placarded equipment shall be liable for the penalties provided by this code.
108.6 Abatement methods. The owner, operator or occupant of a building, premises or equipment deemed unsafe by the code official shall abate or cause to be abated or corrected such unsafe conditions either by repair, rehabilitation, demolition or other approved corrective action.
108.7 Record. The code official shall cause a report to be filed on an unsafe condition. The report shall state the occupancy of the structure and the nature of the unsafe condition.
      (9)   Section 109 Emergency Measures.
109.1 Imminent danger. When, in the opinion of the code official, there is imminent danger of failure or collapse of a building or structure which endangers life, or when any structure or part of a structure has fallen and life is endangered by the occupation of the structure, or when there is actual or potential danger to the building occupants or those in the proximity of any structure because of explosives, explosive fumes or vapors or the presence of toxic fumes, gases or materials, or operation of defective or dangerous equipment, the code official is hereby authorized and empowered to order and require the occupants to vacate the premises forthwith. The code official shall cause to be posted at each entrance to such structure a notice reading as follows: "This Structure Is Unsafe and Its Occupancy Has Been Prohibited by the Code Official." It shall be unlawful for any person to enter such structure except for the purpose of securing the structure, making the required repairs, removing the hazardous condition or of demolishing the same.
109.2 Temporary safeguards. Notwithstanding other provisions of this code, whenever, in the opinion of the code official, there is imminent danger due to an unsafe condition, the code official shall order the necessary work to be done, including the boarding up of openings, to render such structure temporarily safe whether or not the legal procedure herein described has been instituted; and shall cause such other action to be taken as the code official deems necessary to meet such emergency.
109.3 Closing streets. When necessary for public safety, the code official shall temporarily close structures and close, or order the authority having jurisdiction to close, sidewalks, streets, public ways and places adjacent to unsafe structures, and prohibit the same from being utilized.
109.4 Emergency repairs. For the purposes of this section, the code official shall employ the necessary labor and materials to perform the required work as expeditiously as possible.
109.5 Costs of emergency repairs. Costs incurred in the performance of emergency work shall be paid by the jurisdiction. The legal counsel of the jurisdiction shall institute appropriate action against the owner of the premises where the unsafe structure is or was located for the recovery of such costs.
109.6 Hearing. Any person ordered to take emergency measures shall comply with such order forthwith. Any affected person shall thereafter, upon petition directed to the Planning Commission be afforded a hearing as described in this code.
      (10)   Section 110 Demolition.
110.1 General. The code official shall order the owner of any premises upon which is located any structure, which in the code official's judgment after review is so deteriorated or dilapidated or has become so out of repair as to be dangerous, unsafe, insanitary or otherwise unfit for human habitation or occupancy, and such that it is unreasonable to repair the structure, to demolish and remove such structure; or if such structure is capable of being made safe by repairs, to repair and make safe and sanitary, or to board up and hold for future repair or to demolish and remove at the owner's option; or where there has been a cessation of normal construction of any structure for a period of more than two years, the code official shall order the owner to demolish and remove such structure, or board up until future repair. Boarding the building up for future repair shall not extend beyond one year, unless approved by the building official.
110.2 Notices and orders. All notices and orders shall comply with Section 107.
110.3 Failure to comply. If the owner of a premises fails to comply with a demolition order within the time prescribed, the code official shall cause the structure to be demolished and removed, either through an available public agency or by contract or arrangement with private persons, and the cost of such demolition and removal shall be charged against the real estate upon which the structure is located and shall be a lien upon such real estate.
110.4 Salvage materials. When any structure has been ordered demolished and removed, the governing body or other designated officer under said contract or arrangement aforesaid shall have the right to sell the salvage and valuable materials at the highest price obtainable. The net proceeds of such sale, after deducting the expenses of such demolition and removal, shall be promptly remitted with a report of such sale or transaction, including the items of expense and the amounts deducted, for the person who is entitled thereto, subject to any order of a court. If such a surplus does not remain to be turned over, the report shall so state.
      (11)   Section 111 Means of Appeal.
111.1 Application for appeal. Any person directly affected by a decision of the code official or a notice or order issued under this code shall have the right to appeal to the Planning Commission, provided that a written application for appeal is filed with the Clerk of Council within 15 days after the day the decision, notice or order was served. An application for appeal shall be based on a claim that the true intent of this code or the rules legally adopted thereunder have been incorrectly interpreted, the provisions of this code do not fully apply, or the requirements of this code are adequately satisfied by other means.
111.2 Review of Suspected Violations of Environmental Requirements. The Planning Commission may, at the request of the code official, review any suspected violations of this code referred to it by said code official and submit a written recommendation to the code official.
111.3 Review of Violation Orders When Prosecution is Requested. If the code official believes that an alleged violation of this code should be prosecuted, the code official shall issue a show cause order to the alleged violator advising him or her that he or she has five (5) days from the receipt of the order to show cause, in writing, to the Clerk of Council as agent for the Planning Commission why the prosecution should not proceed. If the Clerk of Council receives a timely statement of cause from the alleged violator, the matter shall be referred to the Planning Commission for consideration by it at its next regular meeting and notice of such meeting shall be given to the alleged violator by the Clerk of Council. At its meeting to consider the alleged violator's statement of cause, the Planning Commission shall afford an opportunity to both sides to be heard and shall issue an order affirming, modifying or reversing the action of the code official, which order shall be final and not subject to appeal. If no timely statement of cause is filed by the alleged violator or if the Planning Commission affirms the order of the code official or modifies it in such a way that prosecution is appropriate, the Code Official shall refer the matter to the Department of Law for prosecution or such other action as the Municipal Attorney or his or her designee shall deem appropriate.
111.4 Hiring of Consultants. The Planning Commission with the approval of the City Manager or the City Council, may, in special instances, temporarily retain the services of a consultant to assist the Planning Commission in performing its duties.
111.5 Additional Powers. The Planning Commission shall have all additional powers granted by the City Council.
111.6 Appointment of Staff Assistants by Manager. The City Manager shall appoint staff members as necessary to assist the Planning Commission.
111.7 Appeals to the City Council. Any person, firm or corporation, any officer, department, board or agency of the Municipality, or any interested elector of the Municipality, who or which has been aggrieved or affected by any decision of the Planning Commission may petition for appeal from such decision to the City Council by filing the petition with the Clerk of Council within fifteen (15) days from the date of the decision and setting forth the facts of the case. The Clerk of Council shall immediately inform the City Manager and City Council of receipt of such petition. Upon receipt of notification of the filing of said petition requesting an appeal, the City Council shall, within thirty days of said notification, determine by a majority vote of the entire membership of Council whether it will accept said petition for review. Said determination shall be at the sole discretion of City Council. If the Council determines to accept said appeal, the Council shall hold a public hearing on such appeal not later than forty-five days after such appeal has been filed with its Clerk. A simple majority of the Council membership shall affirm, reverse or modify the decision appealed from, and its decision shall be final. In the event of an appeal to the City Council, all orders of the code official or the Planning Commission pertaining to that appeal shall be stayed pending a decision by the City Council.
111.8 Official Records; Public Inspections. An official record shall be kept of all business and activities of the Planning Commission and other departments and officials specified in the provisions of this code, and all such records shall be open to public inspection at all appropriate times and under reasonable regulations established by the code official to maintain the integrity and security of such records.
      (12)   Section 112 Stop Work Order.
112.1 Authority. Whenever the code official finds any work regulated by this code being performed in a manner contrary to the provisions of this code or in a dangerous or unsafe manner, the code official is authorized to issue a stop work order.
112.2 Issuance. A stop work order shall be in writing and shall be given to the owner of the property, to the owner's authorized agent, or to the person doing the work, or shall be posted in a conspicuous place in or about the structure affected by such notice. Upon issuance of a stop work order, the cited work shall immediately cease. The stop work order shall state the reason for the order and the conditions under which the cited work is authorized to resume.
112.3 Emergencies. Where an emergency exists, the code official shall not be required to give a written notice prior to stopping the work.
112.4 Failure to comply. Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be subject to penalties as set forth in Section 106.4.
   (b)   Chapter 2 Definitions.
      (1)   Section 201 General.
201.1 Scope. Unless otherwise expressly stated, the following terms shall, for the purposes of this code, have the meanings shown in this chapter.
201.2 Interchangeability. Words stated in the present tense include the future; words stated in the masculine gender include the feminine and neuter; the singular number includes the plural and the plural, the singular.
201.3 Terms defined in other codes. Where terms are not defined in this code and are defined in the Ohio Building Code, Ohio Revised Code, Residential Code of Ohio, and the National Electric Code as amended by the Centerville Municipal Code and the Centerville Zoning Code, such terms shall have the meanings ascribed to them as stated in those codes.
201.4 Terms not defined. Where terms are not defined through the methods authorized by this section, such terms shall have ordinarily accepted meanings such as the context implies.
201.5 Parts. Whenever the words "dwelling unit," "dwelling," "premises," "building," "rooming house," "rooming unit," "housekeeping unit" or "story" are stated in this code, they shall be construed as though they were followed by the words "or any part thereof."
      (2)   Section 202 General Definitions.
   ANCHORED. Secured in a manner that provides positive connection.
   APPROVED. Approved by the code official.
   BASEMENT. That portion of a building which is partly or completely below grade.
   BATHROOM. A room containing plumbing fixtures including a bathtub or shower.
   BEDROOM. Any room or space used or intended to be used for sleeping purposes in either a dwelling or sleeping unit.
   CODE OFFICIAL. The official who is charged with the administration and enforcement of this code, or any duly authorized representative.
   CONDEMN. To adjudge unfit for occupancy.
   CORD. A unit of volume used for measuring stacked firewood, equal to 128 cu. ft., usually specified as 8 ft. long, 4 ft. wide, and 4 ft. high.
   COST OF SUCH DEMOLITION OR EMERGENCY REPAIRS. The costs shall include the actual costs of the demolition or repair of the structure less revenues obtained if salvage was conducted prior to demolition or repair. Costs shall include, but not be limited to, expenses incurred or necessitated related to demolition or emergency repairs, such as asbestos survey and abatement if necessary; costs of inspectors, testing agencies or experts retained relative to the demolition or emergency repairs; costs of testing; surveys for other materials that are controlled or regulated from being dumped in a landfill; title searches; mailing(s); postings; recording; and attorney fees expended for recovering of the cost of emergency repairs or to obtain or enforce an order of demolition made by a code official, the governing body or board of appeals.
   DETACHED. When a structural element is physically disconnected from another and that connection is necessary to provide a positive connection.
   DETERIORATION. To weaken, disintegrate, corrode, rust or decay and lose effectiveness.
   DWELLING UNIT. A single unit providing complete, independent living facilities for one or more persons, including permanent provisions for living, sleeping, eating, cooking and sanitation.
   EASEMENT. That portion of land or property reserved for present or future use by a person or agency other than the legal fee owner(s) of the property. The easement shall be permitted to be for use under, on or above said lot or lots.
   EQUIPMENT SUPPORT. Those structural members or assemblies of members or manufactured elements, including braces, frames, lugs, snuggers, hangers or saddles, that transmit gravity load, lateral load and operating load between the equipment and the structure.
   EXTERIOR PROPERTY. The open space on the premises and on adjoining property under the control of owners or operators of such premises.
   EXTERMINATION. The control and elimination of insects, rats or other pests by eliminating their harborage places; by removing or making inaccessible materials that serves as their food; by poison spraying, fumigating, trapping or by any other approved pest elimination methods.
   GARBAGE. The animal or vegetable waste resulting from the handling, preparation, cooking and consumption of food.
   GUARD. A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to a lower level.
   HABITABLE SPACE. Space in a structure for living, sleeping, eating or cooking. Bathrooms, toilet rooms, closets, halls, storage or utility spaces, and similar areas are not considered habitable spaces.
   HISTORIC BUILDING. Any building or structure that is one or more of the following:
      1.   Listed or certified as eligible for listing, by the State Historic Preservation Officer or the Keeper of the National Register of Historic Places, in the National Register of Historic Places.
      2.   Designated as historic under an applicable state or local law.
      3.   Certified as a contributing resource within a National Register or state or locally designated historic district.
   HOUSEKEEPING UNIT. A room or group of rooms forming a single habitable space equipped and intended to be used for living, sleeping, cooking and eating which does not contain, within such a unit, a toilet, lavatory and bathtub or shower.
   IMMINENT DANGER. A condition which could cause serious or life-threatening injury or death at any time.
   INFESTATION. The presence, within or contiguous to, a structure or premises of insects, rodents, vermin or other pests.
   INOPERABLE MOTOR VEHICLE. A vehicle which cannot be driven upon the public streets for reason including but not limited to being unlicensed, wrecked, abandoned, in a state of disrepair, or incapable of being moved under its own power.
   JUNK. Scrap metal, vehicular parts, or any dismantled, partially dismantled, non-operative, or discarded machinery, appliance, equipment, or boat, or part thereof, stored on exterior property areas outside of a completely enclosed structure. Any item of tangible personal property designed to be used in an environment protected from the elements, such as inside a building, shall be presumed to be junk if the item is stored outside.
   LABELED. Equipment, materials, or products to which has been affixed a label, seal, symbol or other identifying mark of a nationally recognized testing laboratory, approved agency or other organization concerned with product evaluation that maintains periodic inspection of the production of the above-labeled items and by whose labeling indicates either that the equipment, material or product meets identified standards or has been tested and found suitable for a specified purpose.
   LET FOR OCCUPANCY or LET. To permit, provide or offer possession or occupancy of a dwelling, dwelling unit, rooming unit, building, premise or structure by a person who is or is not the legal owner of record thereof, pursuant to a written or unwritten lease, agreement or license, or pursuant to a recorded or unrecorded agreement of contract for the sale of land.
   NEGLECT. The lack of proper maintenance for a building or structure.
   OCCUPANCY. The purpose for which a building or portion thereof is utilized or occupied.
   OCCUPANT. Any individual living or sleeping in a building, or having possession of a space within a building.
   OPENABLE AREA. That part of a window, skylight or door which is available for unobstructed ventilation and which opens directly to the outdoors.
   OPERATOR. Any person who has charge, care or control of a structure or premises which is let or offered for occupancy.
   OWNER. Any person, agent, operator, firm or corporation having a legal or equitable interest in the property; or recorded in the official records of the state, county or municipality as holding title to the property: or otherwise having control of the property, including the guardian of the estate of any such person, and the executor or administrator of the estate of such person if ordered to take possession of real property by a court.
   PERSON. An individual corporation, partnership or any other group acting as a unit.
   PEST ELIMINATION. The control and elimination of insects, rodents or other pests by eliminating their harborage places; by removing or making inaccessible materials that serve as their food or water; by other approved pest elimination methods.
   PREMISES. A lot, plot or parcel of land, easement or public way, including any structures thereon.
   PUBLIC WAY. Any street, alley or similar parcel of land essentially unobstructed from the ground to the sky, which is deeded, dedicated or otherwise permanently appropriated to the public for public use.
   ROOMING HOUSE. A building arranged or occupied for lodging, with or without meals, for compensation and not occupied as a one- or two-family dwelling.
   ROOMING UNIT. Any room or group of rooms forming a single habitable unit occupied or intended to be occupied for sleeping or living, but not for cooking purposes.
   RUBBISH. Combustible and noncombustible waste materials, except garbage; the term shall include the residue from the burning of wood, coal, coke and other combustible materials, paper, rags, cartons, boxes, wood, excelsior, rubber, leather, tree branches, yard trimmings, tin cans, metals, mineral matter, glass, crockery and dust and other similar materials.
   SLEEPING UNIT. A room or space in which people sleep, which can also include permanent provisions for living, eating and either sanitation or kitchen facilities, but not both. Such rooms and spaces that are also part of a dwelling unit are not sleeping units.
   STRICT LIABILITY OFFENSE. An offense in which the prosecution in a legal proceeding is not required to prove criminal intent as a part of its case. It is enough to prove that the defendant either did an act which was prohibited, or failed to do an act which the defendant was legally required to do.
   STRUCTURE. That which is built or constructed or a portion thereof.
   TARP. A temporary protective covering.
   TENANT. A person, corporation, partnership or group, whether or not the legal owner of record, occupying a building or portion thereof as a unit.
   TOILET ROOM. A room containing a water closet or urinal but not a bathtub or shower.
   ULTIMATE DEFORMATION. The deformation at which failure occurs and which shall be deemed to occur if the sustainable load reduces to 80 percent or less of the maximum strength.
   VENTILATION. The natural or mechanical process of supplying conditioned or unconditioned air to, or removing such air from, any space.
   WORKMANLIKE. Executed in a skilled manner; e.g., generally plumb, level, square, in line, undamaged and without marring adjacent work.
   YARD. An open space on the same lot with a structure.
   (c)   Chapter 3 General Requirements.
      (1)   Section 301 General.
301.1 Scope. The provisions of this chapter shall govern the minimum conditions and the responsibilities of persons for maintenance of structures, equipment and exterior property.
301.2 Responsibility. The owner of the premises shall maintain the structures and exterior property in compliance with these requirements, except as otherwise provided for in this code. A person shall not occupy as owner-occupant or permit another person to occupy premises which are not in a sanitary and safe condition and which do not comply with the requirements of this chapter. Occupants of a dwelling unit, rooming unit or housekeeping unit are responsible for keeping in a clean, sanitary and safe condition that part of the dwelling unit, rooming unit, housekeeping unit or premises which they occupy and control.
301.3 Vacant structures and land. Vacant structures and premises thereof or vacant land shall be maintained in a clean, safe, secure and sanitary condition as provided herein so as not to cause a blighting problem or adversely affect the public health or safety.
      (2)   Section 302 Exterior Property Areas.
302.1 Sanitation. All exterior property and premises shall be maintained in a clean, safe and sanitary condition. The occupant shall keep that part of the exterior property which such occupant occupies or controls in a clean and sanitary condition.
302.2 Grading and drainage. All premises shall be graded and maintained to prevent the erosion of soil and to prevent the accumulation of stagnant water thereon, or within any structure located thereon.
   Exception: Approved retention areas and reservoirs.
302.3 Sidewalks and driveways. All sidewalks, walkways, stairs, driveways, parking spaces and similar areas shall be kept in a proper state of repair, and maintained free from hazardous conditions. All traffic control devices including striping shall be kept in a proper state of repair.
302.4 Weeds, Vines or Grass. All premises and exterior property shall be maintained free from weeds, vines and grass in accordance with Section 660.14 of the Centerville Municipal Code. Upon failure of the owner or agent having charge of a property to cut and destroy weeds, vines or grass after service of a notice of violation, they shall be subject to prosecution in accordance with Section 106.3 and/or the remedy set forth in 660.14 of the Centerville Municipal Code.
302.5 Rodent harborage. All structures and exterior property shall be kept free from rodent harborage and infestation. Where rodents are found, they shall be promptly exterminated by approved processes which will not be injurious to human health. After extermination, proper precautions shall be taken to eliminate rodent harborage and prevent re-infestation.
302.6 Exhaust vents. Pipes, ducts, conductors, fans or blowers shall not discharge gases, steam, vapor, hot air, grease, smoke, odors or other gaseous or particulate wastes directly upon abutting or adjacent public or private property or that of another tenant.
302.7 Accessory structures. All accessory structures, including detached garages, sheds, fences and walls, shall be maintained structurally sound and in good repair.
302.8 Motor vehicles. Except as provided for in other regulations and in Section 660.07 of the Centerville Municipal Code, no inoperative or unlicensed motor vehicle shall be parked, kept or stored on any premises, and no vehicle shall at any time be in a state of major disassembly, disrepair, or in the process of being stripped or dismantled. Painting of vehicles is prohibited unless conducted inside an approved spray booth.
   Exception: A vehicle of any type is permitted to undergo major overhaul, including body work, provided that such work is performed inside a structure or similarly enclosed area designed and approved for such purposes.
302.9 Defacement of property. No person shall willfully or wantonly damage, mutilate or deface any exterior surface of any structure or building on any private or public property by placing thereon any marking, carving or graffiti. It shall be the responsibility of the owner to restore said surface to an approved state of maintenance and repair.
302.10 Outside Storage. In residential zones all outdoor storage for a continuous period exceeding fifteen (15) days shall be effectively screened from view; and storage of miscellaneous items must be within enclosed structures or screened from view. Storage of miscellaneous items must be within enclosed structures or screened as required by the UDO. No person shall accumulate, cause to be accumulated, or allow to be accumulated junk upon any property located within the City.
302.11 Use of tarps. The use of tarps is limited to a period not to exceed thirty (30) days. Tarps cannot be used to hide or screen other storage violations.
302.12 Storage of firewood. The storage of firewood is limited to six (6) cords. Firewood must be stacked and piled in a reasonably compact and orderly fashion within the rear or side yard.
302.13 Brush piles. No brush pile may exceed the size of 2x2x4 feet. Brush piles are not permitted in a front yard and are limited to one per property. All fallen tree limbs shall be removed.
302.14 Construction equipment. Unless construction equipment is actively being used for construction purposes on the property upon which the equipment is located, all construction equipment must not remain outside more than fifteen days.
302.15 Remedy Vacant or Unattended Properties. Whenever the Code Official becomes aware of the existence of a vacant or unattended property which has not been maintained in a clean, safe and sanitary manner as described in Section 302.1, the Code Official shall give or cause to be given as provided in this Code, to the owner of the property, written notice of such violation and requiring the unclean, unsafe or unsanitary conditions to be removed. If an owner fails to remove the unclean, unsafe or unsanitary conditions within the time specified on the notice and order, the Code Official may remove or cause to be removed the unclean, unsafe, unsanitary conditions and may employ the necessary labor to perform such work or cause it to be done by the appropriate City Department.
   All expenses incurred by the removal of the unclean, unsafe or unsanitary condition, together with an administrative charge of $100.00 for each notice processed, shall be reported to the Finance Director. The owner or owners shall be billed directly by certified or first class mail for the expenses incurred. If after thirty (30) days, such amount remains unpaid, the Finance Director shall certify the total amount of the expenses, the name of the owner of the land and a sufficient description of the premises to the County Auditor, to be entered on the tax duplicate, to be a lien on the land from the date of entry and to be collected as other taxes and assessments returned to the City with the general fund.
302.16 Vegetation. All plant materials (especially trees and shrubs) which are dead, afflicted with decay, disease or insect infestation, or otherwise considered dangerous to other plant material, property or persons, shall be properly removed or appropriately treated. All sound plant materials (especially trees and shrubs) shall be properly maintained.
302.17 Drainage Ways. Owners are obligated to maintain drainage ways in the same manner as the rest of their property. These tasks include all normal and routine maintenance such as mowing grass and weeding, removing brush and other vegetation, removing obstructions such as fallen trees and limbs and policing their yards for litter and other debris. Drainage ways shall be graded and maintained to prevent the erosion of soil and to prevent the accumulation of stagnant water thereon and shall be maintained free from weeds, vines and grass in accordance with Section 660.14 of the Centerville Municipal Code.
      (3)   Section 303 Swimming Pools, Spas and Hot Tubs.
303.1 Swimming pools. Swimming pools shall be maintained in a clean and sanitary condition, and in good repair.
303.2 Enclosures. Private swimming pools, hot tubs and spas, containing water more than 24 inches (610 mm) in depth shall be completely surrounded by a fence or barrier at least 60 inches in height above the finished ground level measured on the side of the barrier away from the pool. Gates and doors in such barriers shall be self-closing and self-latching. Where the self-latching device is less than 60 inches (1,372 mm) above the bottom of the gate, the release mechanism shall be located on the pool side of the gate. Self-closing and self-latching gates shall be maintained such that the gate will positively close and latch when released from an open position of 6 inches (152 mm) from the gatepost. No existing pool enclosure shall be removed, replaced or changed in a manner that reduces its effectiveness as a safety barrier.
   Exception: Spas or hot tubs with a safety cover that complies with ASTM F1346 shall be exempt from the provisions of this section.
      (4)   Section 304 Exterior Structure.
304.1 General. The exterior of a structure shall be maintained in good repair, structurally sound and sanitary so as not to pose a threat to the public health, safety or welfare.
   304.1.1 Unsafe conditions. The following conditions shall be determined as unsafe and shall be repaired or replaced to comply with the Ohio Basic Building Code or the International Existing Building Code as required for existing buildings:
      1.   The nominal strength of any structural member is exceeded by nominal loads, the load effects or the required strength;
      2.   The anchorage of the floor or roof to walls or columns, and of walls and columns to foundations is not capable of resisting all nominal loads or load effects;
      3.   Structures or components thereof that have reached their limit state;
      4.   Siding and masonry joints including joints between the building envelope and the perimeter of windows, doors and skylights are not maintained, weather resistant or water tight;
      5.   Structural members that have evidence of deterioration or that are not capable of safely supporting all nominal loads and load effects;
      6.   Foundation systems that are not firmly supported by footings, are not plumb and free from open cracks and breaks, are not properly anchored or are not capable of supporting all nominal loads and resisting all load effects;
      7.   Exterior walls that are not anchored to supporting and supported elements or are not plumb and free of holes, cracks or breaks and loose or rotting materials, are not properly anchored or are not capable of supporting all nominal loads and resisting all load effects;
      8.   Roofing or roofing components that have defects that admit rain, roof surfaces with inadequate drainage, or any portion of the roof framing that is not in good repair with signs of deterioration, fatigue or without proper anchorage and incapable of supporting all nominal loads and resisting all load effects;
      9.   Flooring and flooring components with defects that affect serviceability or flooring components that show signs of deterioration or fatigue, are not properly anchored or are incapable of supporting all nominal loads and resisting all load effects; Veneer, cornices, belt courses, corbels, trim, wall facings and similar decorative features not properly anchored or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects;
      10.   Overhang extensions or projections including, but not limited to, trash chutes, canopies, marquees, signs, awnings, fire escapes, standpipes and exhaust ducts not properly anchored or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects;
      11.   Exterior stairs, decks, porches, balconies and all similar appurtenances attached thereto, including guards and handrails, are not structurally sound, not properly anchored or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects; or
      12.   Chimneys, cooling towers, smokestacks and similar appurtenances not structurally sound or not properly anchored, or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects.
   Exceptions:
      1.   When substantiated otherwise by an approved method.
      2.   Demolition of unsafe conditions shall be permitted when approved by the code official.
304.2 Protective treatment. All exterior surfaces, including but not limited to, doors, door and window frames, cornices, porches, trim, balconies, decks and fences shall be maintained in good condition. Exterior wood surfaces, other than decay-resistant woods, shall be protected from the elements and decay by painting or other protective covering or treatment. Peeling, flaking and chipped paint shall be eliminated and surfaces repainted. All siding and masonry joints as well as those between the building envelope and the perimeter of windows, doors, and skylights shall be maintained weather resistant and water tight. All metal surfaces subject to rust or corrosion shall be coated to inhibit such rust and corrosion and all surfaces with rust or corrosion shall be stabilized and coated to inhibit future rust and corrosion. Oxidation stains shall be removed from exterior surfaces. Surfaces designed for stabilization by oxidation are exempt from this requirement.
304.3 Premises identification. Buildings shall have approved address numbers placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm).
304.4 Structural members. All structural members shall be maintained free from deterioration, and shall be capable of safely supporting the imposed dead and live loads.
304.5 Foundation walls. All foundation walls shall be maintained plumb and free from open cracks and breaks and shall be kept in such condition so as to prevent the entry of rodents and other pests.
304.6 Exterior walls. All exterior walls shall be free from holes, breaks, and loose or rotting materials; and maintained weatherproof and properly surface coated where required to prevent deterioration.
304.7 Roofs and drainage. The roof and flashing shall be sound, tight and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof drains, gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall not be discharged in a manner that creates a public nuisance.
304.8 Decorative features. All cornices, belt courses, corbels, terra cotta trim, wall facings and similar decorative features shall be maintained in good repair with proper anchorage and in a safe condition. All exterior lighting must be in safe working order. All exterior features must be kept in good repair and safe condition, including but not limited to, glass.
304.9 Overhang extensions. All overhang extensions including, but not limited to canopies, marquees, signs, metal awnings, fire escapes, standpipes and exhaust ducts shall be maintained in good repair and be properly anchored so as to be kept in a sound condition. When required, all exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials, such as paint or similar surface treatment.
304.10 Stairways, decks, porches and balconies. Every exterior stairway, deck, porch and balcony, and all appurtenances attached thereto, shall be maintained structurally sound, in good repair, with proper anchorage and capable of supporting the imposed loads.
304.11 Chimneys and towers. All chimneys, cooling towers, smoke stacks, and similar appurtenances shall be maintained structurally safe and sound, and in good repair. All exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials, such as paint or similar surface treatment.
304.12 Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition.
304.13 Window, skylight and door frames. Every window, skylight, door and frame shall be kept in sound condition, good repair and weather tight.
   304.13.1 Glazing. All glazing materials shall be maintained free from cracks and holes.
   304.13.2 Openable windows. Every window, other than a fixed window, shall be easily openable and capable of being held in position by window hardware.
304.14 Insect screens. During the period from April 1 to December 1, every door, window and other outside opening required for ventilation of habitable rooms, food preparation areas, food service areas or any areas where products to be included or utilized in food for human consumption are processed, manufactured, packaged or stored shall be supplied with approved tightly fitting screens of not less than 16 mesh per inch (16 mesh per 25 mm), and every screen door used for insect control shall have a self-closing device in good working condition.
   Exception: Screens shall not be required where other approved means, such as air curtains or insect repellent fans, are employed.
304.15 Doors. All exterior doors, door assemblies and hardware shall be maintained in good condition. Locks at all entrances to dwelling units and sleeping units shall tightly secure the door. Locks on means of egress doors shall be in accordance with Section 702.3. Every door available as an exit shall be capable of being opened from the inside.
304.16 Basement hatchways. Every basement hatchway shall be maintained to prevent the entrance of rodents, rain and surface drainage water.
304.17 Guards for basement windows. Every basement window that is openable shall be supplied with rodent shields, storm windows or other approved protection against the entry of rodents.
304.18 Building security. Doors, windows or hatchways for dwelling units, room units or housekeeping units shall be provided with devices designed to provide security for the occupants and property within.
   304.18.1 Doors. Doors providing access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased or let shall be equipped with a deadbolt lock designed to be readily openable from the side from which egress is to be made without the need for keys, special knowledge or effort and shall have a lock throw of not less than 1 inch (25 mm). Such deadbolt locks shall be installed according to the manufacturer's specifications and maintained in good working order. For the purpose of this section, a sliding bolt shall not be considered an acceptable deadbolt lock.
   304.18.2 Windows. Operable windows located in whole or in part within 6 feet (1828 mm) above ground level or a walking surface below that provide access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased or let shall be equipped with a window sash locking device.
   304.18.3 Basement hatchways. Basement hatchways that provide access to a dwelling unit, rooming unit or house-keeping unit that is rented, leased or let shall be equipped with devices that secure the units from unauthorized entry.
304.19 Gates. Exterior gates, gate assemblies, operator systems if provided, and hardware shall be maintained in good condition. Latches at all entrances shall tightly secure the gates.
      (5)   Section 305 Interior Structure.
305.1 General. The interior of a structure and equipment therein shall be maintained in good repair, structurally sound and in a sanitary condition. Occupants shall keep that part of the structure which they occupy or control in a clean and sanitary condition. Every owner of a structure containing a rooming house, housekeeping units, a hotel, a dormitory, two or more dwelling units or two or more nonresidential occupancies, shall maintain, in a clean and sanitary condition, the shared or public areas of the structure and exterior property.
   305.1.1 Unsafe conditions. The following conditions shall be determined as unsafe and shall be repaired or replaced to comply with the Ohio Basic Building Code or the International Existing Building Code as required for existing buildings:
      1.   The nominal strength of any structural member is exceeded by nominal loads, the load effects or the required strength;
      2.   The anchorage of the floor or roof to walls or columns, and of walls and columns to foundations is not capable of resisting all nominal loads or load effects;
      3.   Structures or components thereof that have reached their limit state;
      4.   Structural members are incapable of supporting nominal loads and load effects;
      5.   Stairs, landings, balconies and all similar walking surfaces, including guards and handrails, are not structurally sound, not properly anchored or are anchored with connections not capable of supporting all nominal loads and resisting all load effects;
      6.   Foundation systems that are not firmly supported by footings are not plumb and free from open cracks and breaks, are not properly anchored or are not capable of supporting all nominal loads and resisting all load effects.
   Exceptions:
      1.   When substantiated otherwise by an approved method.
      2.   Demolition of unsafe conditions shall be permitted when approved by the code official.
305.2 Structural members. All structural members shall be maintained structurally sound, and be capable of supporting the imposed loads.
305.3 Interior surfaces. All interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected.
305.4 Stairs and walking surfaces. Every stair, ramp, landing, balcony, porch, deck or other walking surface shall be maintained in sound condition and good repair.
305.5 Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition.
305.6 Interior doors. Every interior door shall fit reasonably well within its frame and shall be capable of being opened and closed by being properly and securely attached to jambs, headers or tracks as intended by the manufacturer of the attachment hardware.
      (6)   Section 306 Component Serviceability.
306.1 General. The components of a structure and equipment therein shall be maintained in good repair, structurally sound and in a sanitary condition.
   306.1.1 Unsafe conditions. Where any of the following conditions cause the component or system to be beyond its limit state, the component or system shall be determined as unsafe and shall be repaired or replaced to comply with the Ohio Basic Building Code or the International Existing Building Code as required for existing buildings:
      1.   Soils that have been subjected to any of the following conditions:
         1.1.   Collapse of footing or foundation system;
         1.2.   Damage to footing, foundation, concrete or other structural element due to soil expansion;
         1.3.   Adverse effects to the design strength of footing, foundation, concrete or other structural element due to a chemical reaction from the soil;
         1.4.   Inadequate soil as determined by a geotechnical investigation;
         1.5.   Where the allowable bearing capacity of the soil is in doubt; or
         1.6.   Adverse effects to the footing, foundation, concrete or other structural element due to the ground water table.
      2.   Concrete that has been subjected to any of the following conditions:
         2.1.   Deterioration;
         2.2.   Ultimate deformation;
         2.3.   Fractures;
         2.4.   Fissures;
         2.5.   Spalling;
         2.6.   Exposed reinforcement; or
         2.7.   Detached, dislodged or failing connections.
      3.   Aluminum that has been subjected to any of the following conditions:
         3.1.   Deterioration;
         3.2.   Corrosion;
         3.3.   Elastic deformation;
         3.4.   Ultimate deformation;
         3.5.   Stress or strain cracks;
         3.6.   Joint fatigue; or
         3.7.   Detached, dislodged or failing connections.
      4.   Masonry that has been subjected to any of the following conditions:
         4.1.   Deterioration;
         4.2.   Ultimate deformation;
         4.3.   Fractures in masonry or mortar joints;
         4.4.   Fissures in masonry or mortar joints;
         4.5.   Spalling;
         4.6.   Exposed reinforcement; or
         4.7.   Detached, dislodged or failing connections.
      5.   Steel that has been subjected to any of the following conditions:
         5.1.   Deterioration;
         5.2.   Elastic deformation;
         5.3.   Ultimate deformation;
         5.4.   Metal fatigue; or
         5.5.   Detached, dislodged or failing connections.
      6.   Wood that has been subjected to any of the following conditions:
         6.1.   Ultimate deformation;
         6.2.   Deterioration;
         6.3.   Damage from insects, rodents and other vermin;
         6.4.   Fire damage beyond charring;
         6.5.   Significant splits and checks;
         6.6.   Horizontal shear cracks;
         6.7.   Vertical shear cracks;
         6.8.   Inadequate support;
         6.9.   Detached, dislodged or failing connections; or
         6.10. Excessive cutting and notching.
   Exceptions:
      1.   When substantiated otherwise by an approved method.
      2.   Demolition of unsafe conditions shall be permitted when approved by the code official.
      (7)   Section 307 Handrails and Guardrails.
307.1 General. Every exterior and interior flight of stairs having more than four risers shall have a handrail on one side of the stair and every open portion of a stair, landing, balcony, porch, deck, ramp or other walking surface which is more than 30 inches (762 mm) above the floor or grade below shall have guards. Handrails shall not be less than 30 inches (762 mm) high or more than 42 inches (1,067 mm) high measured vertically above the nosing of the tread or above the finished floor of the landing or walking surfaces. Guards shall not be less than 30 inches (762 mm) high above the floor of the landing, balcony, porch, deck, or ramp or other walking surface.
   Exception: Guards shall not be required where exempted by the adopted building code.
      (8)   Section 308 Rubbish and Garbage.
308.1 Accumulation of rubbish or garbage. All exterior property and premises, and the interior of every structure, shall be free from any accumulation of rubbish or garbage.
308.2 Disposal of rubbish. Every occupant of a structure shall dispose of all rubbish in a clean and sanitary manner by placing such rubbish in approved containers.
   308.2.1 Rubbish storage facilities. The owner of every occupied premises shall supply approved covered containers for rubbish, and the owner of the premises shall be responsible for the removal of rubbish.
   308.2.2 Refrigerators. Refrigerators and similar equipment not in operation shall not be discarded, abandoned or stored on premises without first removing the doors.
308.3 Disposal of garbage. Every occupant of a structure shall dispose of garbage in a clean and sanitary manner by placing such garbage in an approved garbage disposal facility or approved garbage containers.
   308.3.1 Garbage facilities. The owner of every dwelling shall supply an approved leak proof, covered, outside garbage container.
   308.3.2 Containers. Unless provided by the refuse hauler, the owner, operator, or occupant of every establishment producing garbage shall provide, and at all times cause to be utilized, approved leak proof containers provided with close-fitting covers for the storage of such materials until removed from the premises for disposal Places of storage shall comply with the provisions of the Unified Development Ordinance.
      (9)   Section 309 Pest Elimination.
309.1 Infestation. All structures shall be kept free from insect and rodent infestation. All structures in which insects or rodents are found shall be promptly exterminated by approved processes that will not be injurious to human health. After extermination, proper precautions shall be taken to prevent re-infestation.
309.2 Owner. The owner of any structure shall be responsible for extermination within the structure prior to renting or leasing the structure.
309.3 Single occupant. The occupant of a one-family dwelling or of a single-tenant nonresidential structure shall be responsible for pest elimination on the premises.
309.4 Multiple occupancy. The owner of a structure containing two or more dwelling units, a multiple occupancy, a rooming house or a nonresidential structure shall be responsible for extermination in the public or shared areas of the structure and exterior property. If infestation is caused by failure of an occupant to prevent such infestation in the area occupied, the occupant and owner shall be responsible for pest extermination.
309.5 Occupant. The occupant of any structure shall be responsible for the continued rodent and pest-free condition of the structure.
   Exception: Where the infestations are caused by defects in the structure, the owner shall be responsible for pest extermination.
   (d)   Chapter 4 Light, Ventilation and Occupancy Limitations.
      (1)   Section 401 General.
401.1 Scope. The provisions of this chapter shall govern the minimum conditions and standards for light, ventilation and space for occupying a structure.
401.2 Responsibility. The owner of the structure shall provide and maintain light, ventilation and space conditions in compliance with these requirements. A person shall not occupy as owner-occupant, or permit another person to occupy, any premises that do not comply with the requirements of this chapter.
401.3 Alternative devices. In lieu of the means for natural light and ventilation herein prescribed, artificial light or mechanical ventilation complying with the Ohio Basic Building Code shall be permitted.
      (2)   Section 402 Light.
402.1 Habitable spaces. Every habitable space shall have at least one window of approved size facing directly to the outdoors or to a court. The minimum total glazed area for every habitable space shall be 8 percent of the floor area of such room. Wherever walls or other portions of a structure face a window of any room and such obstructions are located less than 3 feet (914 mm) from the window and extend to a level above that of the ceiling of the room, such window shall not be deemed to face directly to the outdoors nor to a court and shall not be included as contributing to the required minimum total window area for the room.
   Exception: Where natural light for rooms or spaces without exterior glazing areas is provided through an adjoining room, the unobstructed opening to the adjoining room shall be not less than 8 percent of the floor area of the interior room or space, but not less than 25 square feet (2.33 m2), whichever is greater. The exterior glazing area shall be based on the total floor area being served.
402.2 Common halls and stairways. Every common hall and stairway in residential occupancies, other than in one- and two-family dwellings, shall be lighted at all times with at least a 60-watt standard incandescent light bulb for each 200 square feet (19 m2) of floor area or equivalent illumination, provided that the spacing between lights shall not be greater than 30 feet (9,144 mm). In other than residential occupancies, means of egress, including exterior means of egress, and stairways shall be illuminated at all times so that the building space served by the means of egress is occupied with a minimum of 1 foot candle (11 lux) at floors, landings and treads.
402.3 Other spaces. All other spaces shall be provided with natural or artificial light sufficient to permit the maintenance of sanitary conditions, and the safe occupancy of the space and utilization of the appliances, equipment and fixtures.
      (3)   Section 403 Ventilation.
403.1 Habitable spaces. Every habitable space shall have at least one openable window. The total openable area of the window in every room shall be equal to at least 45 percent of the minimum glazed area required in Section 402.1.
   Exception: Where rooms and spaces without openings to the outdoors are ventilated through an adjoining room, the unobstructed opening to the adjoining room shall be at least 8 percent of the floor area of the interior room or space, but not less than 25 square feet (2.33 m2). The ventilation openings to the outdoors shall be based on a total floor area being ventilated.
403.2 Bathrooms and toilet rooms. Every bathroom and toilet room shall comply with the ventilation requirements for habitable spaces as required by Section 403.1, except that a window shall not be required in such spaces equipped with a mechanical ventilation system. Air exhausted by a mechanical ventilation system from a bathroom or toilet room shall discharge to the outdoors and shall not be recirculated.
403.3 Cooking facilities. Unless approved through the certificate of occupancy, cooking shall not be permitted in any rooming unit or dormitory unit, and a cooking facility or appliance shall not be permitted to be present in the rooming unit or dormitory unit.
   Exceptions:
      1.   Where specifically approved in writing by the code official.
      2.   Devices such as coffee pots and microwave ovens shall not be considered cooking appliances.
403.4 Process ventilation. Where injurious, toxic, irritating or noxious fumes, gases, dusts or mists are generated, a local exhaust ventilation system shall be provided to remove the contaminating agent at the source. Air shall be exhausted to the exterior and not be recirculated to any space.
403.5 Clothes dryer exhaust. Clothes dryer exhaust systems shall be independent of all other systems and shall be exhausted outside the structure in accordance with the manufacturer's instructions.
   Exception: Listed and labeled condensing (ductless) clothes dryers.
      (4)   Section 404 Occupancy Limitations.
404.1 Privacy. Dwelling units, hotel units, housekeeping units, rooming units and dormitory units shall be arranged to provide privacy and be separate from other adjoining spaces.
404.2 Minimum room widths. A habitable room, other than a kitchen, shall not be less than 7 feet (2,134 mm) in any plan dimension. Kitchens shall have a clear passageway of not less than 3 feet (914 mm) between counterfronts and appliances or counterfronts and walls.
404.3 Minimum ceiling heights. Habitable spaces, hallways, corridors, laundry areas, bathrooms, toilet rooms and habitable basement areas shall have a clear ceiling height of not less than 7 feet (2,134 mm).
   Exceptions:
      1.   In one- and two-family dwellings, beams or girders spaced not less than 4 feet (1,219 mm) on center and projecting not more than 6 inches (152 mm) below the required ceiling height.
      2.   Basement rooms in one- and two-family dwellings occupied exclusively for laundry, study or recreation purposes, having a ceiling height of not less than 6 feet 8 inches (2,033 mm) with not less than 6 feet 4 inches (1,932 mm) of clear height under beams, girders, ducts and similar obstructions.
      3.   Rooms occupied exclusively for sleeping, study or similar purposes and having a sloped ceiling over all or part of the room, with a clear ceiling height of at least 7 feet (2,134 mm) over not less than one-third of the required minimum floor area. In calculating the floor area of such rooms, only those portions of the floor area with a clear ceiling height of 5 feet (1,524 mm) or more shall be included.
404.4 Bedroom and living room requirements. Every bedroom and living room shall comply with the requirements of Sections 404.4.1 through 404.4.5.
   404.4.1 Room area. Every living room shall contain at least 120 square feet (11.2 m2) and every bedroom shall contain at least 70 square feet (6.5 m2) and every bedroom occupied by more than one person shall contain not less than 50 square feet (4.6 m2) of floor area for each occupant thereof.
   404.4.2 Access from bedrooms. Bedrooms shall not constitute the only means of access to other bedrooms or habitable spaces and shall not serve as the only means of egress from other habitable spaces.
      Exception: Units that contain fewer than two bedrooms.
   404.4.3 Water closet accessibility. Every bedroom shall have access to at least one water closet and one lavatory without passing through another bedroom. Every bedroom in a dwelling unit shall have access to at least one water closet and lavatory located in the same story as the bedroom or an adjacent story.
   404.4.4 Prohibited occupancy. Kitchens and non-habitable spaces shall not be used for sleeping purposes.
   404.4.5 Other requirements. Bedrooms shall comply with the applicable provisions of this code including, but not limited to, the light, ventilation, room area, ceiling height and room width requirements of this chapter; the plumbing facilities and water-heating facilities requirements of Chapter 5; the heating facilities and electrical receptacle requirements of Chapter 6; and the smoke detector and emergency escape requirements of Chapter 7.
404.5 Overcrowding. Dwelling units shall not be occupied by more occupants than permitted by the minimum area requirements of Table 404.5.
   TABLE 404.5
   MINIMUM AREA REQUIREMENTS
 
SPACE
MINIMUM AREA IN SQUARE FEET
1-2 occupants
3-5 occupants
6 or more occupants
Living rooma, b
120
120
150
Dining rooma, b
No requirement
80
100
Bedrooms
Shall comply with Section 404.4.1
For SI: 1 square foot = 0.0929 m2.
a. See Section 404.5.2 for combined living room/dining room spaces.
b. See Section 404.5.1 for limitations on determining the minimum occupancy area for sleeping purposes.
 
   404.5.1 Sleeping area. The minimum occupancy area required by Table 404.5 shall not be included as a sleeping area in determining the minimum occupancy area for sleeping purposes. Sleeping areas shall comply with Section 404.4.
   404.5.2 Combined spaces. Combined living room and dining room spaces shall comply with the requirements of Table 404.5 if the total area is equal to that required for separate rooms and if the space is located so as to function as a combination living room/dining room.
404.6 Efficiency unit. Nothing in this section shall prohibit an efficiency living unit from meeting the following requirements:
   1.   A unit occupied by not more than two occupants shall have a clear floor area of not less than 220 square feet (20.4 m2). A unit occupied by three occupants shall have a clear floor area of not less than 320 square feet (29.7 m2). These required areas shall be exclusive of the areas required by Items 2 and 3.
   2   The unit shall be provided with a kitchen sink, cooking appliance and refrigeration facilities, each having a clear working space of not less than 30 inches (762 mm) in front. Light and ventilation conforming to this code shall be provided.
   3.   The unit shall be provided with a separate bathroom containing a water closet, lavatory and bathtub or shower.
   4.   The maximum number of occupants shall be three.
404.7 Food preparation. All spaces to be occupied for food preparation purposes shall contain suitable space and equipment to store, prepare and serve foods in a sanitary manner. There shall be adequate facilities and services for the sanitary disposal of food wastes and refuse, including facilities for temporary storage.
   (e)   Chapter 5 Plumbing Facilities and Fixture Requirements
      (1)   Section 501 General.
501.1 Scope. The provisions of this chapter shall govern the minimum plumbing systems, facilities and plumbing fixtures to be provided.
501.2 Responsibility. The owner of the structure shall provide and maintain such plumbing facilities and plumbing fixtures in compliance with these requirements. A person shall not occupy as owner-occupant or permit another person to occupy any structure or premises which does not comply with the requirements of this chapter.
      (2)   Section 502 Required Facilities.
502.1 Dwelling units. Every dwelling unit shall contain its own bathtub or shower, lavatory, water closet and kitchen sink which shall be maintained in a sanitary, safe working condition. The lavatory shall be placed in the same room as the water closet or located in close proximity to the door leading directly into the room in which such water closet is located. A kitchen sink shall not be used as a substitute for the required lavatory.
502.2 Rooming houses. At least one water closet, lavatory and bathtub or shower shall be supplied for each four rooming units.
502.3 Hotels. Where private water closets, lavatories and baths are not provided, one water closet, one lavatory and one bath-tub or shower having access from a public hallway shall be provided for each ten occupants.
502.4 Employees' facilities. A minimum of one water closet, one lavatory and one drinking facility shall be available to employees.
   502.4.1 Drinking facilities. Drinking facilities shall be a drinking fountain, water cooler, bottled water cooler or disposable cups next to a sink or water dispenser. Drinking facilities shall not be located in toilet rooms or bathrooms.
   502.5 Public toilet facilities. Public toilet facilities shall be maintained in a safe sanitary and working condition in accordance with the International Plumbing Code. Except for periodic maintenance or cleaning, public access and use shall be provided to the toilet facilities at all times during occupancy of the premises.
      (3)   Section 503 Toilet Rooms.
503.1 Privacy. Toilet rooms and bathrooms shall provide privacy and shall not constitute the only passageway to a hall or other space, or to the exterior. A door and interior locking device shall be provided for all common or shared bathrooms and toilet rooms in a multiple dwelling.
503.2 Location. Toilet rooms and bathrooms serving hotel units, rooming units or dormitory units or housekeeping units, shall have access by traversing not more than one flight of stairs and shall have access from a common hall or passageway.
503.3 Location of employee toilet facilities. Toilet facilities shall have access from within the employees' working area. The required toilet facilities shall be located not more than one story above or below the employees' working area and the path of travel to such facilities shall not exceed a distance of 500 feet (152 m). Employee facilities shall either be separate facilities or combined employee and public facilities.
   Exception: Facilities that are required for employees in storage structures or kiosks, which are located in adjacent structures under the same ownership, lease or control, shall not exceed a travel distance of 500 feet (152 m) from the employees' regular working area to the facilities.
503.4 Floor surface. In other than dwelling units, every toilet room floor shall be maintained to be a smooth, hard, nonabsorbent surface to permit such floor to be easily kept in a clean and sanitary condition.
      (4)   Section 504 Plumbing Systems and Fixtures.
504.1 General. All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. All plumbing fixtures shall be maintained in a safe, sanitary and functional condition.
504.2 Fixture clearances. Plumbing fixtures shall have adequate clearances for usage and cleaning.
504.3 Plumbing system hazards. Where it is found that a plumbing system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service, inadequate venting, cross connection, backsiphonage, improper installation, deterioration or damage or for similar reasons, the code official shall require the defects to be corrected to eliminate the hazard.
      (5)   Section 505 Water System.
505.1 General. Every sink, lavatory, bathtub or shower, drinking fountain, water closet or other plumbing fixture shall be properly connected to either a public water system or to an approved private water system. All kitchen sinks, lavatories, laundry facilities, bathtubs and showers shall be supplied with hot or tempered and cold running water in accordance with the Ohio Basic Building Code.
505.2 Contamination. The water supply shall be maintained free from contamination, and all water inlets for plumbing fixtures shall be located above the flood-level rim of the fixture. Shampoo basin faucets, janitor sink faucets and other hose bibs or faucets to which hoses are attached and left in place, shall be protected by an approved atmospheric-type vacuum breaker or an approved permanently attached hose connection vacuum breaker.
505.3 Supply. The water supply system shall be installed and maintained to provide a supply of water to plumbing fixtures, devices and appurtenances in sufficient volume and at pressures adequate to enable the fixtures to function properly, safely, and free from defects and leaks.
505.4 Water heating facilities. Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a temperature of not less than 110°F (43°C). A gas-burning water heater shall not be located in any bathroom, toilet room, bedroom or other occupied room normally kept closed, unless adequate combustion air is provided. An approved combination temperature and pressure-relief valve and relief valve discharge pipe shall be properly installed and maintained on water heaters.
505.5 Non-potable water reuse systems. Non-potable water reuse systems and rainwater collection and conveyance systems shall be maintained in a safe and sanitary condition. Where such systems are not properly maintained, the systems shall be repaired to provide for safe and sanitary conditions, or the system shall be abandoned in accordance with Section 505.5.1.
   505.5.1 Abandonment of systems. Where a non-potable water reuse system or a rainwater collection and distribution system is not maintained or the owner ceases use of the system, the system shall be abandoned in accordance with the Ohio Building Code or other laws and regulations.
      (6)   Section 506 Sanitary Drainage System.
506.1 General. All plumbing fixtures shall be properly connected to either a public sewer system or to an approved private sewage disposal system.
506.2 Maintenance. Every plumbing stack, vent, waste and sewer line shall function properly and be kept free from obstructions, leaks and defects.
506.3 Grease interceptors. Grease interceptors and automatic grease removal devices shall be maintained in accordance with this code and the manufacturer's installation instructions. Grease interceptors and automatic grease removal devices shall be regularly serviced and cleaned to prevent the discharge of oil, grease, and other substances harmful or hazardous to the building drainage system, the public sewer, the private sewage disposal system or the sewage treatment plant or processes. Records of maintenance, cleaning and repairs shall be available for inspection by the code official.
      (7)   Section 507 Storm Drainage.
507.1 General. Drainage of roofs and paved areas, yards and courts, and other open areas on the premises shall not be discharged in any manner that creates a public nuisance.
   (f)   Chapter 6 Mechanical and Electrical Requirements.
      (1)   Section 601 General.
601.1 Scope. The provisions of this chapter shall govern the minimum mechanical and electrical facilities and equipment to be provided.
601.2 Responsibility. The owner of the structure shall provide and maintain mechanical and electrical facilities and equipment in compliance with these requirements. A person shall not occupy as owner-occupant or permit another person to occupy any premises which does not comply with the requirements of this chapter.
      (2)   Section 602 Heating Facilities.
602.1 Facilities required. Heating facilities shall be provided in structures as required by this section.
602.2 Residential occupancies. Dwellings shall be provided with heating facilities capable of maintaining a room temperature of 65°F (18°C) in all habitable rooms, bathrooms and toilet rooms based on the Ohio Basic Building Code. Cooking appliances shall not be used to provide space heating to meet the requirements of this section.
602.3 Heat supply. Every owner and operator of any building who rents, leases or lets one or more dwelling units or sleeping units on terms, either expressed or implied, to furnish heat to the occupants thereof shall supply heat during the period from October 1 to May 15 to maintain a temperature of not less than 65°F (18°C) in all habitable rooms, bathrooms, and toilet rooms.
602.4 Occupiable work spaces. Indoor occupiable work spaces shall be supplied with heat during the period from October 1 to May 15 to maintain a temperature of not less than 65°F (18°C) during the period the spaces are occupied.
   Exceptions:
      1.   Processing, storage and operation areas that require cooling or special temperature conditions.
      2.   Areas in which persons are primarily engaged in vigorous physical activities.
602.5 Room temperature measurement. The required room temperatures shall be measured 3 feet (914 mm) above the floor near the center of the room and 2 feet (610 mm) inward from the center of each exterior wall.
      (3)   Section 603 Mechanical Equipment.
603.1 Mechanical equipment and appliances. All mechanical appliances, fireplaces, solid fuel-burning appliances, cooking appliances and water heating appliances shall be properly installed and maintained in a safe working condition, and shall be capable of performing the intended function.
603.2 Removal of combustion products. All fuel-burning equipment and appliances shall be connected to an approved chimney or vent.
   Exception: Fuel-burning equipment and appliances which are labeled for unvented operation.
603.3 Clearances. All required clearances to combustible materials shall be maintained.
603.4 Safety controls. All safety controls for fuel-burning equipment shall be maintained in effective operation.
603.5 Combustion air. A supply of air for complete combustion of the fuel and for ventilation of the space containing the fuel-burning equipment shall be provided for the fuel-burning equipment.
603.6 Energy conservation devices. Devices intended to reduce fuel consumption by attachment to a fuel-burning appliance, to the fuel supply line thereto, or to the vent outlet or vent piping therefrom, shall not be installed unless labeled for such purpose and the installation is specifically approved.
      (4)   Section 604 Electrical Facilities.
604.1 Facilities required. Every occupied building shall be provided with an electrical system in compliance with the requirements of this section and Section 605.
604.2 Service. The size and usage of appliances and equipment shall serve as a basis for determining the need for additional facilities in accordance with the Ohio Basic Building Code. Dwelling units shall be served by a three-wire, 120/240 volt, single-phase electrical service having a rating of not less than 100 amperes.
604.3 Electrical system hazards. Where it is found that the electrical system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service, improper fusing, insufficient receptacle and lighting outlets, improper wiring or installation, deterioration or damage, or for similar reasons, the code official shall require the defects to be corrected to eliminate the hazard.
   604.3.1 Abatement of electrical hazards associated with water exposure. The provisions of this section shall govern the repair and replacement of electrical systems and equipment that have been exposed to water.
      604.3.1.1 Electrical equipment. Electrical distribution equipment, motor circuits, power equipment, transformers, wire, cable, flexible cords, wiring devices, ground fault circuit interrupters, surge protectors, molded case circuit breakers, low-voltage fuses, luminaires, ballasts, motors and electronic control, signaling and communication equipment that have been exposed to water shall be replaced in accordance with the provisions of the Ohio Basic Building Code.
         Exception: The following equipment shall be allowed to be repaired where an inspection report from the equipment manufacturer or approved manufacturer's representative indicates that the equipment has not sustained damage that requires replacement:
         1.   Enclosed switches, rated 600 volts or less;
         2.   Busway, rated 600 volts or less;
         3.   Panelboards, rated 600 volts or less;
         4.   Switchboards, rated 600 volts or less;
         5.   Fire pump controllers, rated 600 volts or less;
         6.   Manual and magnetic motor controllers;
         7.   Motor control centers;
         8.   Alternating current high-voltage circuit breakers;
         9.   Low-voltage power circuit breakers;
         10.   Protective relays, meters and current transformers;
         11.   Low- and medium-voltage switchgear;
         12.   Liquid-filled transformers;
         13.   Cast-resin transformers;
         14.   Wire or cable that is suitable for wet locations and whose ends have not been exposed to water;
         15.   Wire or cable, not containing fillers, that is suitable for wet locations and whose ends have not been exposed to water;
         16.   Luminaires that are listed as submersible;
         17.   Motors;
         18.   Electronic control, signaling and communication equipment.
   604.3.2 Abatement of electrical hazards associated with fire exposure. The provisions of this section shall govern the repair and replacement of electrical systems and equipment that have been exposed to fire.
      604.3.2.1 Electrical equipment. Electrical switches, receptacles and fixtures, including furnace, water heating, security system and power distribution circuits, that have been exposed to fire, shall be replaced in accordance with the provisions of the Ohio Basic Building Code.
         Exception: Electrical switches, receptacles and fixtures that shall be allowed to be repaired where an inspection report from the equipment manufacturer or approved manufacturer's representative indicates that the equipment has not sustained damage that requires replacement.
      (5)   Section 605 Electrical Equipment.
605.1 Installation. All electrical equipment, wiring and appliances shall be properly installed and maintained in a safe and approved manner.
605.2 Receptacles. Every habitable space in a dwelling shall contain at least two separate and remote receptacle outlets. Every laundry area shall contain at least one grounded-type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain at least one grounded- type receptacle. Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection. All receptacle outlets shall have the appropriate faceplate cover for the location.
605.3 Luminaires. Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room and furnace room shall contain at least one electric luminaire. Pool and spa luminaires over 15 V shall have ground fault circuit interrupter protection.
605.4 Wiring. Flexible cords shall not be used for permanent wiring, or for running through doors, windows, or cabinets, or concealed within walls, floors, or ceilings.
      (6)   Section 606 Elevators, Escalators and Dumbwaiters.
606.1 General. Elevators, dumbwaiters and escalators shall be maintained in compliance with ASME A17.1. The most current certification of inspection shall be on display at all times within the elevator or attached to the escalator or dumbwaiter, be available for public inspection in the office of the building operator, or be posted in a publicly conspicuous location approved by the code official. The inspection and tests shall be performed at not less than the periodic intervals listed in ASME A17.1, Appendix N, except where otherwise specified by the authority having jurisdiction.
606.2 Elevators. In buildings equipped with passenger elevators, at least one elevator shall be maintained in operation at all times when the building is occupied.
   Exception: Buildings equipped with only one elevator shall be permitted to have the elevator temporarily out of service for testing or servicing.
      (7)   Section 607 Duct Systems.
607.1 General. Duct systems shall be maintained free of obstructions and shall be capable of performing the required function.
   (g)   Chapter 7 Fire Safety Requirements.
      (1)   Section 701 General.
701.1 Scope. The provisions of this chapter, along with the Ohio Fire Code and the International Fire Code, shall govern the minimum conditions and standards for fire safety relating to structures and exterior premises, including fire safety facilities and equipment to be provided.
701.2 Responsibility. The owner of the premises shall provide and maintain such fire safety facilities and equipment in compliance with these requirements. A person shall not occupy as owner-occupant or permit another person to occupy any premises that do not comply with the requirements of this chapter.
      (2)   Section 702 Means of Egress.
702.1 General. A safe, continuous and unobstructed path of travel shall be provided from any point in a building or structure to the public way. Means of egress shall comply with the Ohio Fire Code and the International Fire Code.
702.2 Width of Aisles. In all mercantile occupancies, the minimum clear-aisle width shall be forty-four inches (1,118 millimeters), except that in occupancies with an occupant load of fifty or less, the clear-aisle width shall be not less than thirty-six inches (914 millimeters).
702.3 Locked doors. All means of egress doors shall be readily openable from the side from which egress is to be made without the need for keys, special knowledge or effort, except where the door hardware conforms to that permitted by the Ohio Basic Building Code.
702.4 Emergency escape openings. Required emergency escape openings shall be maintained in accordance with the code in effect at the time of construction, and the following. Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles, grates or similar devices are permitted to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the escape and rescue opening.
702.5 Accumulations and Storage of Waste, Refuse or Explosive or Flammable Materials
   702.5.1 Waste and Refuse. Waste, refuse or other similar materials shall not be allowed to accumulate in stairways, passageways, doors, windows, fire escapes or other means of egress.
   702.5.2 Flammable and Explosive Materials. Highly flammable or explosive matter, such as paints, volatile oils or cleaning fluids, or combustible refuse, such as waste paper, boxes and rags, shall not be accumulated or stored on residential premises, except in reasonable quantities consistent with normal usage.
   702.5.3 Residential Units in Structures Containing Flammable Liquids. A dwelling unit or rooming unit shall not be located within a structure containing an establishment handling, dispensing or storing flammable liquids with a flashpoint of 110 degrees Fahrenheit (forty-three degrees Celsius) or lower, except as provided for in the Ohio Basic Building Code.
   702.5.4 Storage in Nonresidential Structures. Storage of combustible or flammable materials is permitted in nonresidential structures, provided that such materials are confined to approved storage areas and comply with applicable requirements of the Ohio Basic Building Code and the Ohio Fire Code and the International Fire Code, for the appropriate use group classification.
702.6 Exit Signs. All exit signs shall be maintained, illuminated and visible.
702.7 Dual Egress. Every residential building exceeding two stories in height above grade, not counting basements, shall be provided with not less than two approved independent exits from each floor above the second floor, fully accessible from each occupancy on the floor. One and two-family dwellings are excepted from this requirement.
      (3)   Section 703 Fire-resistance Ratings.
703.1 Fire-resistance-rated assemblies. The provisions of this chapter shall govern maintenance of the materials, systems and assemblies used for structural fire resistance and fire-resistance-rated construction separation of adjacent spaces to safeguard against the spread of fire and smoke within a building and the spread of fire to or from buildings.
703.2 Unsafe conditions. Where any components are not maintained and do not function as intended or do not have the fire resistance required by the code under which the building was constructed or altered, such components or portions thereof shall be deemed unsafe conditions in accordance with the Ohio Fire Code and the International Fire Code. Components or portions thereof determined to be unsafe shall be repaired or replaced to conform to that code under which the building was constructed or altered. Where the condition of components is such that any building, structure or portion thereof presents an imminent danger to the occupants of the building, structure or portion thereof, the fire code official shall act in accordance with the Ohio Fire Code and the International Fire Code.
703.3 Maintenance. The required fire-resistance rating of fire-resistance-rated construction, including walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and joint systems, shall be maintained. Such elements shall be visually inspected annually by the owner and repaired, restored or replaced where damaged, altered, breached or penetrated. Records of inspections and repairs shall be maintained. Where concealed, such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel, access door, ceiling tile or entry to the space. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer and any other reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance-rated assemblies shall be protected by self- or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly.
   703.3.1 Fire blocking and draft stopping. Required fire blocking and draft stopping in combustible concealed spaces shall be maintained to provide continuity and integrity of the construction.
   703.3.2 Smoke barriers and smoke partitions. Required smoke barriers and smoke partitions shall be maintained to prevent the passage of smoke. Openings protected with approved smoke barrier doors or smoke dampers shall be maintained in accordance with NFPA 105.
   703.3.3 Fire walls, fire barriers, and fire partitions. Required fire walls, fire barriers and fire partitions shall be maintained to prevent the passage of fire. Openings protected with approved doors or fire dampers shall be maintained in accordance with NFPA 80.
703.4 Opening protectives. Opening protectives shall be maintained in an operative condition in accordance with NFPA 80. The application of field-applied labels associated with the maintenance of opening protectives shall follow the requirements of the approved third-party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be blocked or obstructed, or otherwise made inoperable. Fusible links shall be replaced whenever fused or damaged. Fire door assemblies shall not be modified.
   703.4.1 Signs. Where required by the code official, a sign shall be permanently displayed on or near each fire door in letters not less than 1 inch (25 mm) high to read as follows:
      1.   For doors designed to be kept normally open: FIRE DOOR - DO NOT BLOCK.
      2.   For doors designed to be kept normally closed: FIRE DOOR -KEEP CLOSED.
   703.4.2 Hold-open devices and closers. Hold-open devices and automatic door closers shall be maintained. During the period that such a device is out of service for repairs, the door it operates shall remain in the closed position.
   703.4.3 Door operation. Swinging fire doors shall close from the full-open position and latch automatically. The door closer shall exert enough force to close and latch the door from any partially open position.
703.5 Ceilings. The hanging and displaying of salable goods and other decorative materials from acoustical ceiling systems that are part of a fire-resistance-rated horizontal assembly shall be prohibited.
703.6 Testing. Horizontal and vertical sliding and rolling fire doors shall be inspected and tested annually to confirm operation and full closure. Records of inspections and testing shall be maintained.
703.7 Vertical shafts. Interior vertical shafts, including stairways, elevator hoist ways and service and utility shafts, which connect two or more stories of a building shall be enclosed or protected as required in the Ohio Fire Code and the International Fire Code. New floor openings in existing buildings shall comply with the Ohio Basic Building Code.
703.8 Opening protective closers. Where openings are required to be protected, opening protectives shall be maintained self-closing or automatic-closing by smoke detection. Existing fusible-link-type automatic door-closing devices shall be replaced if the fusible link rating exceeds 135°F (57°C).
      (4)   Section 704 Fire Protection Systems.
704.1 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems, mechanical smoke exhaust systems, and smoke and heat vents shall be maintained in accordance with the Ohio Fire Code and the International Fire Code in an operative condition at all times, and shall be replaced or repaired where defective.
   704.1.1 Installation. Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection where the building is altered or enlarged. Alterations to fire protection systems shall be done in accordance with applicable standards.
   704.1.2 Required fire protection systems. Fire protection systems required by this code, Ohio Fire Code and the International Fire Code or the Ohio Basic Building Code shall be installed, repaired, operated, tested and maintained in accordance with this code. A fire protection system for which a design option, exception or reduction to the provisions of this code, the Ohio Fire Code and the International Fire Code or the Ohio Basic Building Code has been granted shall be considered to be a required system.
   704.1.3 Fire protection systems. Fire protection systems shall be inspected, maintained and tested in accordance with the following Ohio Fire Code and the International Fire Code Code requirements.
      1.   Automatic sprinkler systems, see Section 903.5.
      2.   Automatic fire-extinguishing systems protecting commercial cooking systems, see Section 904.12.5.
      3.   Automatic water mist extinguishing systems, see Section 904.11.
      4.   Carbon dioxide extinguishing systems, see Section 904.8.
      5.   Carbon monoxide alarms and carbon monoxide detection systems, see Section 915.6.
      6.   Clean-agent extinguishing systems, see Section 904.10.
      7.   Dry-chemical extinguishing systems, see Section 904.6.
      8.   Fire alarm and fire detection systems, see Section 907.8.
      9.   Fire department connections, see Sections 912.4 and 912.7.
      10.   Fire pumps, see Section 913.5.
      11.   Foam extinguishing systems, see Section 904.7.
      12.   Halon extinguishing systems, see Section 904.9.
      13.   Single- and multiple-station smoke alarms, see Section 907.10.
      14.   Smoke and heat vents and mechanical smoke removal systems, see Section 910.5.
      15.   Smoke control systems, see Section 909.20.
      16.   Wet-chemical extinguishing systems, see Section 904.5.
704.2 Standards. Fire protection systems shall be inspected, tested and maintained in accordance with the referenced standards listed in Table 704.2 and as required in this section.
TABLE 704.2
FIRE PROTECTION SYSTEM MAINTENANCE STANDARDS
SYSTEM
STANDARD
TABLE 704.2
FIRE PROTECTION SYSTEM MAINTENANCE STANDARDS
SYSTEM
STANDARD
Portable fire extinguishers
NFPA 10
Carbon dioxide fire-extinguishing system
NFPA 12
Halon 1301 fire-extinguishing systems
NFPA 12A
Dry-chemical extinguishing systems
NFPA 17
Wet-chemical extinguishing systems
NFPA 17A
Water-based fire protection systems
NFPA 25
Fire alarm systems
NFPA 72
Smoke and heat vents
NFPA 204
Water-mist systems
NFPA 750
Clean-agent extinguishing systems
NFPA 2001
 
   704.2.1 Records. Records shall be maintained of all system inspections, tests and maintenance required by the referenced standards.
   704.2.2 Records information. Initial records shall include the: name of the installation contractor; type of components installed; manufacturer of the components; location and number of components installed per floor; and manufacturers' operation and maintenance instruction manuals. Such records shall be maintained for the life of the installation.
704.3 Systems out of service. Where a required fire protection system is out of service, the fire department and the fire code official shall be notified immediately and, where required by the fire code official, either the building shall be evacuated or an approved fire watch shall be provided for all occupants left unprotected by the shutdown until the fire protection system has been returned to service. Where utilized, fire watches shall be provided with not less than one approved means for notification of the fire department and shall not have duties beyond performing constant patrols of the protected premises and keeping watch for fires. Actions shall be taken in accordance with the Ohio Fire Code and the International Fire Code to bring the systems back in service.
   704.3.1 Emergency impairments. Where unplanned impairments of fire protection systems occur, appropriate emergency action shall be taken to minimize potential injury and damage. The impairment coordinator shall implement the steps outlined in the Ohio Fire Code and the International Fire Code.
704.4 Removal of or tampering with equipment. It shall be unlawful for any person to remove, tamper with or otherwise disturb any fire hydrant, fire detection and alarm system, fire suppression system or other fire appliance required by this code except for the purposes of extinguishing fire, training, recharging or making necessary repairs.
   704.4.1 Removal of or tampering with appurtenances. Locks, gates, doors, barricades, chains, enclosures, signs, tags and seals that have been installed by or at the direction of the fire code official shall not be removed, unlocked, destroyed or tampered with in any manner.
   704.4.2 Removal of existing occupant-use hose lines. The fire code official is authorized to permit the removal of existing occupant-use hose lines where all of the following apply:
      1.   The installation is not required by the International Fire Code or the Ohio Building Code.
      2.   The hose line would not be utilized by trained personnel or the fire department.
      3.   The remaining outlets are compatible with local fire department fittings.
   704.4.3 Termination of monitoring service. For fire alarm systems required to be monitored by the Ohio Fire Code and the International Fire Code, notice shall be made to the fire code official whenever alarm monitoring services are terminated. Notice shall be made in writing by the provider of the monitoring service being terminated.
704.5 Fire department connection. Where the fire department connection is not visible to approaching fire apparatus, the fire department connection shall be indicated by an approved sign mounted on the street front or on the side of the building. Such sign shall have the letters "FDC" not less than 6 inches (152 mm) high and words in letters not less than 2 inches (51 mm) high or an arrow to indicate the location. Such signs shall be subject to the approval of the fire code official.
   704.5.1 Fire department connection access. Ready access to fire department connections shall be maintained at all times and without obstruction by fences, bushes, trees, walls or any other fixed or movable object. Access to fire department connections shall be approved by the fire chief.
      Exception: Fences, where provided with an access gate equipped with a sign complying with the legend requirements of Section 912.5 of the International Fire Code and a means of emergency operation. The gate and the means of emergency operation shall be approved by the fire chief and maintained operational at all times.
   704.5.2 Clear space around connections. A working space of not less than 36 inches (914 mm) in width, 36 inches (914 mm) in depth and 78 inches (1,981 mm) in height shall be provided and maintained in front of and to the sides of wall-mounted fire department connections and around the circumference of free-standing fire department connections.
704.6 Single- and multiple-station smoke alarms. Single- and multiple-station smoke alarms shall be installed in existing Group I-1 and R occupancies in accordance with Sections 704.6.1 through 704.6.3.
   704.6.1 Where required. Existing Group I-1 and R occupancies shall be provided with single-station smoke alarms in accordance with Sections 704.6.1.1 through Interconnection and power sources shall be in accordance with Sections 704.6.2 and 704.6.3.
      Where the code that was in effect at the time of construction required smoke alarms and smoke alarms complying with those requirements are already provided. Where smoke alarms have been installed in occupancies and dwellings that were not required to have them at the time of construction, additional smoke alarms shall not be required provided that the existing smoke alarms comply with requirements that were in effect at the time of installation.
      Where smoke detectors connected to a fire alarm system have been installed as a substitute for smoke alarms.
      704.6.1.1 Group R-1. Single- or multiple-station smoke alarms shall be installed in all of the following locations in Group R-1:
         1.   In sleeping areas.
         2.   In every room in the path of the means of egress from the sleeping area to the door leading from the sleeping unit.
         3.   In each story within the sleeping unit, including basements. For sleeping units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.
      704.6.1.2 Groups R-2, R-3, R-4 and I-1. Single- or multiple-station smoke alarms shall be installed and maintained in Groups R-2, R-3, R-4 and I-1 regardless of occupant load at all of the following locations:
         1.   On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms.
         2.   In each room used for sleeping purposes.
         3.   In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.
      704.6.1.3 Installation near cooking appliances. Smoke alarms shall not be installed in the following locations unless this would prevent placement of a smoke alarm in a location required by Section 704.6.1.1 or 704.6.1.2.
         1.   Ionization smoke alarms shall not be installed less than 20 feet (6,096 m) horizontally from a permanently installed cooking appliance.
         2.   Ionization smoke alarms with an alarm-silencing switch shall not be installed less than 10 feet (3,048 mm) horizontally from a permanently installed cooking appliance.
         3.   Photoelectric smoke alarms shall not be installed less than 6 feet (1,829 mm) horizontally from a permanently installed cooking appliance.
      704.6.1.4 Installation near bathrooms. Smoke alarms shall be installed not less than 3 feet (914 mm) horizontally from the door or opening of a bathroom that contains a bathtub or shower unless this would prevent placement of a smoke alarm required by Section 704.6.1.1 or 704.6.1.2.
   704.6.2 Interconnection. Where more than one smoke alarm is required to be installed within an individual dwelling or sleeping unit, the smoke alarms shall be interconnected in such a manner that the activation of one alarm will activate all of the alarms in the individual unit. Physical interconnection of smoke alarms shall not be required where listed wireless alarms are installed and all alarms sound upon activation of one alarm. The alarm shall be clearly audible in all bedrooms over background noise levels with all intervening doors closed.
      Exceptions:
         1.   Interconnection is not required in buildings that are not undergoing alterations, repairs or construction of any kind.
         2.   Smoke alarms in existing areas are not required to be interconnected where alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space or basement available that could provide access for interconnection without the removal of interior finishes.
   704.6.3 Power source. Single-station smoke alarms shall receive their primary power from the building wiring provided that such wiring is served from a commercial source and shall be equipped with a battery backup. Smoke alarms with integral strobes that are not equipped with battery backup shall be connected to an emergency electrical system. Smoke alarms shall emit a signal when the batteries are low. Wiring shall be permanent and without a disconnecting switch other than as required for over-current protection.
      Exceptions:
         1.   Smoke alarms are permitted to be solely battery operated in existing buildings where construction is not taking place.
         2.   Smoke alarms are permitted to be solely battery operated in buildings that are not served from a commercial power source.
         3.   Smoke alarms are permitted to be solely battery operated in existing areas of buildings undergoing alterations or repairs that do not result in the removal of interior walls or ceiling finishes exposing the structure, unless there is an attic, crawl space or basement available that could provide access for building wiring without the removal of interior finishes.
   704.6.4 Smoke detection system. Smoke detectors listed in accordance with UL 268 and provided as part of the building's fire alarm system shall be an acceptable alternative to single- and multiple-station smoke alarms and shall comply with the following:
      1.   The fire alarm system shall comply with all applicable requirements in the Ohio Fire Code and the International Fire Code.
      2.   Activation of a smoke detector in a dwelling or sleeping unit shall initiate alarm notification in the dwelling or sleeping unit in accordance with the Ohio Fire Code and the International Fire Code.
      3.   Activation of a smoke detector in a dwelling or sleeping unit shall not activate alarm notification appliances outside of the dwelling or sleeping unit, provided that a supervisory signal is generated and monitored in accordance with the Ohio Fire Code and the International Fire Code.
704.7 Single- and multiple-station smoke alarms. Single and multiple-station smoke alarms shall be tested and maintained in accordance with the manufacturer's instructions. Smoke alarms that do not function shall be replaced. Smoke alarms installed in one- and two-family dwellings shall be replaced not more than 10 years from the date of manufacture marked on the unit, or shall be replaced if the date of manufacture cannot be determined.
      (5)   Section 705 Carbon Monoxide Alarms and Detection.
705.1 General. Carbon monoxide alarms shall be installed in dwellings in accordance with Section 1103.9 of the International Fire Code, except that alarms in dwellings covered by the International Residential Code shall be installed in accordance with Section R315 of that code.
705.2 Carbon monoxide alarms and detectors. Carbon monoxide alarms and carbon monoxide detection systems shall be maintained in accordance with NFPA 720. Carbon monoxide alarms and carbon monoxide detectors that become inoperable or begin producing end-of-life signals shall be replaced.
   Appendix A Boarding Standard
      (1)   A101 General.
A101.1 General. All windows and doors shall be boarded in an approved manner to prevent entry by unauthorized persons. After 30 days doors shall be painted to correspond to the color of the existing structure and windows shall be secured with clear boarding material.
      (2)   A102 Materials.
A102.1 Boarding sheet material. Boarding sheet material shall be minimum 1/2-inch (12.7 mm) thick wood structural panels complying with the Ohio Basic Building Code.
A102.2 Boarding framing material. Boarding framing material shall be minimum nominal 2-inch by 4-inch (51 mm by 102 mm) solid sawn lumber complying with the Ohio Basic Building Code.
A102.3 Boarding fasteners. Boarding fasteners shall be minimum 3/8-inch (9.5 mm) diameter carriage bolts of such a length as required to penetrate the assembly and as required to adequately attach the washers and nuts. Washers and nuts shall comply with the Ohio Basic Building Code.
      (3)   A103 Installation.
A103.1 Boarding installation. The boarding installation shall be in accordance with Figures A103.1(1) and A103.1(2) and Sections A103.2 through A103.5.
A103.2 Boarding sheet material. The boarding sheet material shall be cut to fit the door or window opening neatly or shall be cut to provide an equal overlap at the perimeter of the door or window.
A103.3 Windows. The window shall be opened to allow the carriage bolt to pass through or the window sash shall be removed and stored. The 2-inch by 4-inch (51 mm by 102 mm) strong back framing material shall be cut minimum 2 inches (51 mm) wider than the window opening and shall be placed on the inside of the window opening 6 inches minimum above the bottom and below the top of the window opening. The framing and boarding shall be predrilled. The assembly shall be aligned and the bolts, washers and nuts shall be installed and secured.
A103.4 Door walls. The door opening shall be framed with minimum 2-inch by 4-inch (51 mm by 102 mm) framing material secured at the entire perimeter and vertical members at not more than 24 inches (610 mm) on center. Blocking shall also be secured at not more than 48 inches (1,219 mm) on center vertically. Boarding sheet material shall be secured with screws and nails alternating every 6 inches (152 mm) on center.
A103.5 Doors. Doors shall be secured by the same method as for windows or door openings. One door to the structure shall be available for authorized entry and shall be secured and locked in an approved manner.
      (4)   A104 REFERENCED STANDARD
   IBC-18 Ohio Basic Building Code         A102.1, A102.2, A102.3
 
 
(Ord. 04-11. Passed 2-21-11; Ord. 06-19. Passed 4-15-19; Ord. 13-22. Passed 6-6-22.)