Culverts shall be designed and constructed as follows: Culverts, pipes, or tiles shall be placed under roads at locations in accordance with the Drainage Plan, and/or as necessary to provide outlets for side ditches and stormwater to which they will be subjected. All culverts shall be corrugated aluminum, galvanized corrugated steel, corrugated plastic, or concrete pipe. All culverts installed under driveways or within street rights-of-way shall be a minimum of 12 inches in diameter, and shall be installed prior to placing of the street surface. Pipe end sections shall be installed on all pipes 36 or fewer inches in diameter. All culverts under the roadway shall extend at least the full roadway width, including the shoulders.
(Prior Code, § 152.094) (Ord. 87, passed 4-18-1988)