(A) Requirements.
(1) Requirements. Every dwelling unit and rooming unit shall be supplied with sufficient heat or heating equipment capable of supplying sufficient heat during the period from October 1 to May 15 to maintain a room temperature of not less than 68°F in all habitable areas during the hours between 6:30 a.m. and 10:30 p.m. and maintain a temperature of not less than 60°F during other hours. The temperature shall be measured at a point three feet above the floor and three feet from exterior walls.
(2) Exception. When the exterior temperature falls below 0°F or the wind chill factor falls below 0°F and the heating system is operating at its full capacity, the system must be capable of achieving a minimum room temperature of 60°F at all times.
(B) Climate control. When facilities for interior climate control (heating, cooling and humidity) are integrated, such facilities shall be maintained and operated in accordance with the designed capacity.
(2004 Code, § 141-23) (Ord. 70, passed 9-29-1988; Ord. 02-19, passed 11-21-2002)