1042.09 FORMAT FOR DETAIL PLANS.
   (a)   Standard sheets shall be plan profile sheets of twenty four by thirty six inches.
   (b)   India or other reproducible ink on linen cloth is required.
   (c)   All lettering shall be .125 inch high or larger.
   (d)   The title block shall be six inches by three inches and shall be located in the lower right hand corner. It shall include the sewer district, the development name and section, the engineer's name, seal and signature, the sheet number and the number of sheets.
    (e)   The revision block shall be located left of or above the title block with room for at least three revisions.
   (f)   Scale shall be one inch equals fifty inches or larger for horizontal, and one inch equals five feet or larger for vertical.
   (g)   The signature block on the cover sheet shall include places for the following officials (in order from top to bottom):
      (1)   Council, the Mayor and the Clerk of Council (eight spaces);
      (2)   The Sanitary Engineer;
      (3)   The County Engineer, when the water or sewer service is on or crosses a County road;
      (4)   Directors of service for other political entities, when applicable; and
      (5)   Municipal engineers for other political entities, when applicable.
   (h)   A vicinity map shall be provided to show the location of improvements.
   (i)   If there are five or more sheets, a cover sheet is required which shall contain a signature block and a key map with sheet reference numbers.
   (j)   Each sheet shall have a readily readable north arrow oriented up and/or to the left when possible. The stationing on the plan and profile sheets shall be from left to right and shall take precedence over the north arrow orientation.
   (k)   Each set of plans shall contain the following note: All sanitary sewers and/or water mains and appurtenances thereto shall be constructed in accordance with the specifications of the Department of Service.
   (l)   Profiles for both sewers and water mains shall be shown on the same sheet as the plan view. The profile shall be below the plan, and the ground line shall be taken at the pipe centerline or the road centerline, if noted. The profile shall be lined up under corresponding points on the plan. Existing and proposed grade profiles shall be shown on each profile view.
   (m)   All existing structures in the right-of-way or easement shall be shown in both the plan and profile. Sizes, locations, dimensions and elevations shall be included. Such structures include, but are not limited to:
      (1)   Gas mains;
      (2)   Electric and telephone conduits;
      (3)   Storm sewers;
      (4)   Sanitary sewer lines;
      (5)   Water lines;
      (6)   Telephone poles;
      (7)   Street lights; and
      (8)   All above ground structures which may affect construction.
   (n)   Manholes shall be consecutively numbered from lowest to highest elevations, and elevations and station numbers shall be noted. The first manhole or structure shall be assigned Station 0+00 and shall be the manhole or structure that makes the connection to the existing system. Both manhole and station numbers shall appear on both the plan and the profile.
   (o)   The length, grade and size of each span of sewer shall appear on the profile.
   (p)   The type of pipe material, joints and strength shall be shown in the profile for both sewer and water, using A.S.T.M. nomenclature.
   (q)   The location of all special features, such as concrete encasements, siphons, elevated sewers and special cross sections shall be shown.
   (r)   Details of all special appurtenances, such as manholes, inspection chambers, siphons, regulators, metering devices, elevated sewers, etc., shall be shown.
   (s)   All subdivisions and plat book pages shall be clearly marked, including lot numbers. All properties abutting the improvement shall be shown for full width and depth.
   (t)   The ownership, including deed book page and acreage, of all property not subdivided by a record plat shall be shown.
   (u)   All corporation lines, with dimensions and other information that will fix the exact location, shall be shown on the cover sheet. Section, township, range and U.S.G.S. index number shall be included.
   (v)   Private driveways, lanes and easements, with appropriate dimensions, shall be shown by dashed lines.
   (w)   The locations, descriptions and elevations of all bench marks that are used in connection with the project shall appear on each appropriate sheet.
   (x)   Locations of test borings shall be shown when they are made.
   (y)   Proposed improvements shall be shown as solid dark lines; existing improvements shall be shown as dashed lines.
   (z)   Existing or proposed streets and all streams or water surfaces shall be clearly shown. Contour lines at appropriate intervals shall be shown. (Ord. 9-87. Passed 3-9-87.)