9-2-2-8: RESIDENTIAL CODE AMENDMENTS:
The following additions, insertions and changes shall further apply and shall supersede any and all references listed within the international residential code, 2012 edition:
Section R101.1 Insert "village of Campton Hills".
(2013 Code § 11-1-12)
Section R105.10 Add a new section and the following:
Unique Construction: When a project has unique features, unusual construction sequences or out of the ordinary construction techniques, the building department shall have the authority to require additional documentation to determine code compliance. The building and zoning officer may also add additional fees to the building permit based on the additional inspections required, or to cover the cost of specialized inspections, or outside inspection or testing agencies.
Unique features or unusual construction sequence is a project where the use of features or sequences, which create the need for additional inspections other than those normally requested by the building and zoning officer. The features, or a sequence of operations which creates additional inspections, can create this.
(2013 Code § 11-1-12; amd. 2016 Code)
Section R106.6 Plans On The Job Site Requirements: A copy of approved plans with all revisions shall be kept on the site of the building or work at the time of inspection.
Section R108.1 Payment Of Fees: Add the following:
Insert "Building permit fee schedule shall be determined by ordinance by the village board.".
(2013 Code § 11-1-12)
Section R112 Board Of Appeal: Delete sections R112.1 through 112.4 and insert:
See building code amendments to section 113.
(2013 Code § 11-1-12; amd. 2016 Code)
Section R113.4 Violation Penalties: Insert the following:
The penalties shall be as determined by ordinance by the village board.
Table 301.2(1): The following information shall be inserted in the table:
Ground snow load
25
Wind speed
3 second 90 normal 75
Topographic effects
Yes
Seismic condition
A
Subject to damage from weathering
Severe
Frost line depth
42 inches
Termite
Moderate to heavy (termite shields required)
Winter design temperature
-4 degrees
Ice shield underlayment
Yes
Flood hazard
Village of Campton Hills, August 3, 2009, July 17, 2012
Air freezing index
2000
Mean annual temp
50 degrees
 
Section R302.1 Add the following:
All townhouses and two-family dwellings shall be separated with a minimum of a two-hour fire resistant rated wall assembly.
Section R302.2 Add the following:
The walls between town homes shall have a minimum fire rating of two hours. This rating shall extend beyond the exterior walls for a minimum of 5 feet when the exterior walls are offset.
Section R302.6 Separation: Delete the section and insert the following:
Garage Separation: All one and two family dwellings shall be separated from adjacent interior spaces by a fire partition having a fire resistance rating of not less than one (1) hour. All beams, columns and support walls supporting living spaces shall be protected. The door assembly leading from the garage to the interior space shall carry a one (1) hour fire rating and shall be supplied with an automatic self-closing device. If an attic opening is located within the garage, this opening must also carry a one (1) hour fire resistance rating.
Section R309.1 Delete the section and the following:
Floor Surface:
All garage floors shall be concrete.
Curb: A four (4) inch high concrete curb shall be provided between the garage and residence.
Section R309.5 Fire Sprinklers: Delete the section in its entirety.
Section R309.6 is hereby added to read as follows:
Section R309.6 Free Standing Or Detached Garages: Garages of slab and grade beam construction without footings and permanent foundation walls may be permitted if said garage is separated from the main house or building by no less than ten (10) feet of open space. Said garage shall not be permitted to any connection to the main house or building unless a complete footing and foundation system is provided to a depth of no less than forty-two (42) inches below grade.
(2013 Code § 11-1-12)
Section R310.6 Add the following section to read as follows:
   Notwithstanding anything contained within the IRC to the contrary, any alteration, repair or addition to windows within a sleeping unit or sleeping room identified in Section R310.1 of the IRC shall ensure such alteration, repair or addition shall cause the applicable sleeping unit or sleeping room to be compliant with the requirements for emergency escape and rescue openings as provided in Section R310 of the IRC.
Section R313.2 Automatic Fire Sprinkler Systems In One And Two Family Dwellings: Delete the section in its entirety.
Section R401.3.1 Add new section:
Gutters: All dwellings shall have gutters. The gutters and downspouts shall be designed and installed to discharge the water away from the building.
Sections R403 and R404.3.3 All references to wood footings and foundations are deleted. The use of wood footings and foundations is prohibited.
(2013 Code § 11-1-12)
Section R408.8 New subsection R408.8 is added following subsection R408.7 and shall read as follows:
"R408.7 Concrete Slush Coats In Crawl Spaces: All crawl spaces shall have a minimum of two (2) inch slush coat installed in all residential crawl spaces. A base course shall be installed in accordance with subsection 505.2.2.".
(2013 Code § 11-1-12; amd. 2016 Code)
Section R501.3.1 Add section R501.3.1 Open Web Trusses: The use of open web wood floor trusses and engineered floor joists is not allowed unless drywalled on the bottom side with a minimum of one layer of 5/8 inch drywall or any one-hour fire- rated assembly.
Section R502.7.1 Change as follows:
Joists shall be supported by solid bridging, diagonal bridging (wood or metal) at intervals not exceeding eight (8) feet. The building official may approve alternate methods of bridging.
Delete chapters 25, 26, 27, 28, 29, 30, 31, and 32. Refer to state of Illinois department of public health plumbing code of 2004.
(2013 Code § 11-1-12)
Delete chapters 33, 34, 35, 36, 37, 38, 39, 40, 41 and insert the 2011 edition of NFPA 70 with the amendments listed in section 150.09.
(2013 Code § 11-1-12; amd. 2016 Code)
Referenced standards:
Delete the references to the international plumbing code.
Delete the references to the international private sewage disposal code.
Adopt the following appendices: B, C, F, G, H, K, and O.
(2013 Code § 11-1-12; amd. Ord. O-19-16, 10-1-2019)