(A) New construction and substantial improvements with fully-enclosed areas below the lowest floor which are usable solely for parking vehicles, building access or storage in an area other than a basement and which are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters.
(B) Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria:
(1) A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided;
(2) The bottom of all openings shall be not higher than one foot above grade; and
(3) Openings may be equipped with screens, louvers, valves or other coverings or devices, provided that they permit the automatic entry and exit of floodwaters.
(Prior Code, § 12-217) (Ord. 2010-07, passed 1-11-2011) Penalty, see § 153.99