(a) Ground-mounted.
(1) No earth station shall be constructed in any front or side yard, but shall be constructed to the rear of the residence or main structure.
(2) No earth station, including its concrete base slab or other substructure, shall be constructed less than ten feet from any property line or easement.
(3) No earth station shall be constructed without appropriate evergreen landscaping to reasonably conceal such earth station from view, and the planting shall be completed before final approval of the Zoning Inspector.
(4) No earth station shall be linked, physically or electronically, to a receiver which is not located on the same lot, premises or parcel of land as is the earth station.
(5) An earth station shall not exceed a grade height of twelve feet.
(6) All structural supports shall be of galvanized metal.
(7) Wiring between an earth station and a receiver shall be placed at least four inches beneath the surface of the ground within rigid conduit.
(8) Such earth station shall be designed to withstand a wind force of seventy- five miles per hour without the use of supporting guy wires.
(9) Any driving motor shall be limited to 110v maximum power design and be encased in protective guards.
(10) An earth station must be bonded to a grounding rod.
(11) No earth station shall be constructed upon the roof top of any garage, residential dwelling, church school, apartment building, hospital or any other commercial building or structure.
(Ord. 1353-85. Passed 2-18-85.)