Main and accessory buildings and uses permitted in the Commercial Service District, Limited Industrial District, and General Industrial District shall comply with the following performance standards as a condition precedent to their occupancy and use unless:
(a) All service and manufacturing operations shall be conducted wholly within an enclosed structure complying with the Building Code, and all raw materials, fuel, machinery and equipment, including trucks used in the operations, shall be enclosed within a structure or screened by a substantially solid wall or fence of such nature and height as to conceal all operations and material therein from the view of any observer standing at the grade level at the nearest residential district line or public street.
(b) Storage of all materials in yards or buildings must comply with the Ohio Fire Code and with the ordinances of the Village, and all parts of the buildings, material stored therein, yards and open areas, shall be accessible to fire-fighting equipment.
(c) Solid waste resulting from operations shall be either disposed of, stored in buildings, or enclosed within a wall or fence.
(d) Liquid wastes shall not be discharged into a reservoir, stream, or other open body of water, and if discharged into a public sewer, the wastes shall conform to the regulations set forth in the Northeast Ohio Regional Sewer District's Code of Regulations, and where applicable, the Ohio Environmental Protection Agency.
(e) All operation shall be of a type that will not disseminate dust, smoke, fumes, glare, heat, noxious odors or vibrations beyond the boundaries of the district, nor shall they possess other characteristics equally as objectionable. Smoke emitted shall not exceed the density described as twenty percent opacity, except that for not more than two minutes in any thirty minutes, the emission may be greater than, but shall not exceed, the density of forty percent opacity. Dust and fly-ash shall not exceed 0.3 grains of any solid particles per cubic foot of the conveying gas or air.
(f) Noise shall be muffled so as not to become objectionable due to intermittence, beat frequency or shrillness, and shall not exceed the average intensity of street traffic noise at the nearest Residential District line.
(g) Bulk storage of flammable liquids and gases above ground in tanks, where permitted, shall not be less than 150 feet from a lot line.
(h) Radioactive or electrical disturbances that could adversely affect persons, property or equipment beyond the boundaries of the lot shall not be created.
(Ord. 73-94. Passed 10-4-94.)