§ 152.092 PLAN, PROFILE AND CROSS SECTIONS.
   (A)   The plan and profile shall be drawn, at a scale of not smaller than one inch to 50 feet horizontally and one inch to five feet vertically, on Mylar or equal and not larger than 24 inches by 36 inches of the proposed grading, draining, paving, sanitary sewers and water lines within the subdivision. Such plan and profile will show both the location and elevation of all improvements to be made. The centerline of the plan will be stationed and the location of improvements will be located with regard to this stationing. Such plan shall be accompanied by cross sections of the proposed streets, at a scale of not smaller than one inch to ten feet, on Mylar or equal and not larger than 24 inches by 36 inches. Such cross sections shall be taken at intervals not exceeding 50 feet along the centerline of such streets, and shall extend a minimum of 100 feet left and right of the centerline. Such cross sections shall show the contour of the existing ground and the contour of the proposed pavement, walks and finish grading, and the relative location of the proposed sewers and water lines.
   (B)   Such plan shall include the following information:
      (1)   Name of proposed subdivision;
      (2)   North arrow, scale, date and benchmark with elevation above sea level on each sheet; and
      (3)   Typical cross section of the proposed street right-of-way showing in detail the pavement design, sidewalks and the relative location of the proposed water line, sanitary sewer, storm sewer, electrical, phone, cable television, telecommunications cable and gas line.
(Ord. 09-2001, § 116.85, passed 3-5-2001)