1339.06 EARTH STATION SUPPORT STRUCTURES.
   (a)    Only metal support, galvanized construction, or equal thereto, shall be allowed.
   (b)    Only a concrete base or caissons, depending on soil conditions, shall be employed in line with grade.
   (c)    The structure shall be designed to withstand wind force of up to eighty-five miles per hour in a manner conforming with good engineering practices.
   (d)    Any driving motor shall be limited to 110 volt maximum power design, be encased in protective guards, and be in compliance with requirements as provided in The National Electric Code, Article 800.
   (e)    All underground electrical wiring must be encased in approved PVC conduit or rigid metal conduit with eighteen inch cover and overhead wiring must also meet with the approval of the Commissioner of Buildings and comply with the requirements as provided in The National Electric Code, Article 800 and related articles.
   (f)    The earth station must be bonded to an eight foot grounding rod and in accordance with the requirements as provided in The National Electric Code, Article 250 and related articles.
   (g)    Should guy wires be used, they must be confined within a fenced area or be protected by a suitable shield.
   (h)    The structure must be in conformance with the National Electric Code, Article 800 and related articles as referenced.
(Ord. 2395. Passed 5-15-85.)