§ 50.070 WATER PLANS CHECKLIST.
   Water line plans should, at the minimum, show the following information:
   (A)   Location and dimension of all existing and proposed street and sanitary sewer rights-of-way;
   (B)   Sanitary sewer and storm drain systems dotted in;
   (C)   Invert of storm drains at crossings, storm drains closely paralleled by water lines;
   (D)   Invert of sanitary sewers at crossings and at upstream and downstream manholes;
   (E)   Size, lengths (or stationary) and types of lines (water, storm, sanitary);
   (F)   All tees, gate valves, fire hydrants and blowoffs properly labeled;
   (G)   Legend of symbols;
   (H)   North arrow;
   (I)   Street names;
   (J)   Location(s) of nearest existing valves;
   (K)   Existing pavement and if applicable, width and length of cut;
   (L)   Include "general notes" on all plans;
   (M)   Registered engineer's seal and signature; and
   (N)   Vicinity map, showing location of lines and a visual plan page index.
(Ord. passed 6-21-2011)