§ 52.071 RAIN WATER DRAIN.
   (A)   No rain water drain shall connect with a house drain, catch basin or house sewer pipe which is used for the purpose of collecting, conducting or carrying sewage from said building into a main sanitary sewer.
   (B)   In the event a main storm sewer is located in a street adjoining a building, the rain drains must be connected directly into the storm sewer by means of cast iron pipe or C-425 sewage tile.
   (C)   Where no main storm sewer is located in a street adjoining said premises, all water from the roof of a building shall be carried by means of gutters and outside leaders to a splash block. The ground shall be graded and drained so as to accommodate as much seepage as possible and to prevent drainage upon adjacent property.
   (D)   Inside rain water leaders are prohibited except where a rain water drain in connected to a main storm sewer. Inside rain water leaders shall be constructed of extra heavy cast iron, galvanized wrought iron, galvanized steel, copper or plastic Schedule 40 P.V.C.
   (E)   Outside rain water leaders shall be constructed of metal including galvanized steel or aluminum.
(Ord. 2015-033, passed 11-10-2015)