§ 162.456 NUMBER OF PARKING AND LOADING SPACES REQUIRED.
   Off-street parking and loading spaces shall be provided as indicated in tabular form below. For any use that is not listed in the table, the same amount of parking and loading space shall be provided as is required for the most similar listed use. The Zoning Administrator shall make the determination of similarity.
Use
Parking Spaces Required
Loading Spaces Required (If Any)
Use
Parking Spaces Required
Loading Spaces Required (If Any)
Commercial, Office, Service
Note: all commercial and service uses, unless specifically indicated
1 space per 300 sq. ft. of floor area
To 10,000 sq. ft. of floor area: 1 space
More than 10,000 sq. ft.: 1 space, plus 1 additional space per 50,000 sq. ft. of floor area in excess of 10,000 sq. ft.
Banks, savings and loans (both walk-in and drive-in)
 
To 30,000 sq. ft. of floor area
   Walk-in
1 space per 300 sq. ft. of floor area, plus employee parking
None required
30,001-100,000 sq. ft.: 1 space
More than 100,000 sq. ft.: 1 space, plus 1 additional per 100,000 sq. ft.
   Drive-in teller window
5 spaces per
space per 100,000 sq. ft. of floor area in excess of 100,000 sq. ft.
Beauty and barber shops
2 spaces per chair, plus employee parking
Not applicable
Bowling alleys
4 spaces per bowling lane plus additional spaces as required herein for affiliated uses such as restaurants and taverns
Not applicable, except as required for affiliated uses
Car wash
5 spaces per wash lane
Not applicable
Furniture and appliance stores
1 space per 600 sq. ft. of floor area
To 25,000 sq. ft. of floor area: 2 spaces
More than 25,000 sq. ft. of floor area: 2 spaces, plus 1 additional space per 25,000 sq. ft. of floor area in excess of 25,000 sq. ft.
Home occupations
1 space per 150 sq. ft. of floor area devoted to the home occupation in addition to the parking requirements for the dwelling
Not applicable
Theaters
 
Not applicable
   Indoor
1 space per 4 seats in the largest seating area.
 
   Drive-in
On review by the Administrator
 
Vehicle sales
1 space per 600 sq. ft. of enclosed floor area, plus: Up to 10,000 sq. ft. of open lot area devoted to sale/display of vehicles: 1 space per 2,500 sq. ft. of open lot area above 10,000 sq. ft.: 4 spaces plus 1 additional space per 5,000 sq. ft. of open lot area in excess of 10,000 sq. ft.
To 25,000 sq. ft. of floor area and open lot area: 2 spaces
More than 25,000 sq. ft. of floor area and open lot area: 2 spaces, plus 1 additional space per 25,000 sq. ft. in excess of 25,000 sq. ft.
Dwellings, Lodging
Hotels, motels, rooming houses, lodges
1 space per lodging unit, plus employee parking
1 space if the use has 20,000 sq. ft. or more of floor area
Mobile homes
2 spaces per mobile home
Not applicable
Multiple-family dwellings
 
Not applicable
1 bedroom or less
1.5 spaces per dwelling unit
2 or more bedrooms
2 spaces per dwelling unit
Single-family and two-family dwellings
2 spaces per dwelling unit
Not applicable
Educational, Institutional, Recreational
Churches, auditoriums
1 space per 4 seats in the largest seating area
Not applicable
Hospitals
1 space per 2 beds, plus employee parking
To 50,000 sq. ft. of floor area: l space
50,001-100,000 sq. ft: 2 spaces
100,001-200,000 sq. ft: 3 spaces
Libraries, museums
1 space per 500 sq. ft. of floor area
On review by the Administrator
Nursing homes
1 space per 4 beds
To 50,000 sq. ft. of floor area: 1 space
50,001-100,000 sq. ft.: 2 spaces
100,001-200,000 sq. ft.: 3 spaces
Schools
 
On review by the Administrator
   Elementary and junior high
1 space for every 20 students that the building is designed to accommodate, plus employee parking
 
   Senior High
1 space for every 4 students over 16 yrs. old that the building is designed to accommodate, plus employee parking
 
   Trade schools
1 space for every 3 students that the building is designed to accommodate, plus employee parking
 
Industrial
Any manufacturing, warehousing or other industrial use
Employee parking (1.5 spaces per employee), plus 1 space per company vehicle, plus 1 visitor space per 25 employees on the major shift
To 20,000 sq. ft. of floor area: 1 space
20,001-50,000 sq. ft.: 2 spaces
50,000-90,000 sq. ft.: 3 spaces
Above 90,000 sq. ft.: 3 spaces, plus 1 additional space per 50,000 sq. ft. of floor area in excess of 90,000 sq. ft.
 
(1960 Code, § 60-8-22) (Ord. 4770, passed - -)