921.03 STORM SEWERS.
(a) Pipe Composition, Joints and Fittings. All storm sewers installed and constructed in the Municipality shall be constructed of pipe having joints and fittings as hereinbefore specified or precast bituminous compound joints and fittings or slip-seal or its equal.
(b) Diameters. All storm sewers in single-family, two-family and multiple-family homes shall be of the materials herein specified and shall have a minimum diameter of six inches. Storm sewers in industrial buildings, factories, shops and business establishments shall be of the same material herein specified but shall be of such diameter as the Municipal Engineer shall specify. The Engineer's required sizes shall be based upon the sewage capacity of such industrial building, factory, shop or business establishment.
(Ord 87-5. Passed 1-6-87.)