§ 150.038  UTILITY REQUIREMENTS.
   (A)   Water systems.
      (1)   An accessible, adequate, safe, and palatable supply of water shall be provided in each manufactured home park. Where a county or municipal water supply is available, connection shall be made thereto and its supply used exclusively.
      (2)   When a county or municipal supply is not available, a community water supply shall be developed and its supply used exclusively in accordance with the standards of the Sanitary Engineering Division of the State Board of Health and the County Health Department. Individual wells may be used and must comply with state standards and regulations.
   (B)   Sewage systems.
      (1)   Adequate and safe sewage disposal facilities shall be provided in all manufactured home parks. Collection systems and sewage treatment plants complying with the requirements of the State Department of Water and Air Resources shall be provided. Plans for sewage collection systems and treatment facilities shall be submitted to the State Department of Water and Air Resources. Individual septic tank systems can be considered if soil, topography, and groundwater conditions are favorable.
      (2)   Each manufactured home space shall be provided with at least a four-inch diameter sewer riser pipe. The sewer riser pipe shall be located on each space that the sewer connection to the mobile home drain outlet will approximate a vertical position.
      (3)   A two-foot by two-foot concrete apron shall be installed around all sewer connection riser pipes for support and protection. The sewer connection shall be located a distance of at least 100 feet from a water supply relying on wells. A distance of only ten feet is needed between the septic and water systems when the drinking water is drawn from a community or public water supply.
      (4)   The sewer connection shall have a nominal inside diameter of at least four inches, and the slope of any portion thereof shall be at least one-fourth inch per foot. The sewer connection shall consist of one pipeline only, without any branch fittings. All joints shall be watertight, including connection from trailer to sewer riser pipe.
      (5)   All material used for sewer connection shall be semi-rigid, corrosion resistant, nonabsorbent, and durable. The inner surface shall be smooth.
      (6)   Provision shall be made for plugging the sewer pipe, when a mobile home does not occupy a space. Surface drainage shall be diverted away from the rise. The rim of the riser pipe shall extend at least four inches above-ground elevation.
   (C)   Solid waste disposal systems.
      (1)   The storage, collection, and disposal of solid waste in the manufactured home park shall be so conducted as to create no health hazards, rodent harborage, insect breeding areas, accident or fire hazards, or pollution.
      (2)   For each lot, the minimum requirements will be two cans of at least 30-gallon capacity each, which are elevated at least one foot off the ground. All trash will be contained inside these two cans, or will be subject to penalties and fines outlined at the end of this chapter.
(Ord. passed 10-2-2006)